9. Control Theory for Automation: Fundamentals
نویسنده
چکیده
9.4 Dynamical Systems with Inputs .............. 154 9.4.1 Input-to-State Stability (ISS) ......... 154 9.4.2 Cascade Connections..................... 157 9.4.3 Feedback Connections .................. 157 9.4.4 The Steady-State Response............ 158 9.5 Feedback Stabilization of Linear Systems ................................. 160 9.5.1 Stabilization by Pure State Feedback ................. 160 9.5.2 Observers and State Estimation ...... 161 9.5.3 Stabilization via Dynamic Output Feedback ........ 162
منابع مشابه
Communication in Automation, Including Networking and Wireless
An introduction to the fundamental issues and limitations of communication and networking in automation is given. Digital communication fundamentals are reviewed and networked control systems together with teleoperation are discussed. Issues in both wired and wireless networks are presented.
متن کاملKey Considerations for Powertrain HIL Test
Safety, availability, and cost considerations can make performing thorough tests of embedded control devices using the complete system impractical. Hardware-in-the-loop (HIL) simulation is a real-time test technique used to test these devices more efficiently. During HIL test, the physical system that interfaces to an embedded control device is simulated on real-time hardware, and the outputs o...
متن کاملA New Control Method for Single-Phase Grid-Connected Inverter Using Instantaneous Power Theory
Because of installation for local consumers and since it is free of all contaminations, connecting photovoltaic cells to the grid via single-phase inverter is significantly on the rise. In this paper, a new simple current control is proposed for a single-phase grid-connected voltage source inverter. Using the PQ theory and modelling a single-phase system as an unbalanced three-phase system, a m...
متن کاملA Novel Controller Based on Single-Phase Instantaneous p-q Power Theory for a Cascaded PWM Transformer-less STATCOM for Voltage Regulation
In this paper, dynamic performance of a transformerless cascaded PWM static synchronous shunt compensator (STATCOM) based on a novel control scheme is investigated for bus voltage regulation in a 6.6kV distribution system. The transformerless STATCOM consists of a thirteen-level cascaded H-bridge inverter, in which each voltage source H-bridge inverter should be equipped with a floating and iso...
متن کاملRobust compliant motion for manipulators, part I: The fundamental concepts of compliant motion
A method for the design of controllers of constrained manipulators in the presence of model uncertainties is developed. The controller must carry out fine maneuvers when the manipulator is not constrained, and compliant motion, with or without interaction-force measurement, when the manipulator is constrained. At the same time stability must be preserved if bounded uncertainties are allowed in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009