Early experience of tomotherapy-based intensity-modulated radiotherapy for breast cancer treatment.
نویسندگان
چکیده
AIMS New technology - specifically intensity-modulated radiotherapy (IMRT) - is now being applied to breast radiotherapy and a recent dosimetric analysis confirmed the advantages of IMRT over 'wedge-only' plans. Such application to everyday practice raises new issues and here we present the early experience of IMRT-based breast irradiation in a single centre. MATERIALS AND METHODS We present cases of breast cancer treated by Tomotherapy-based IMRT, where the perceived advantages of IMRT are considerable. Cases presented are bilateral disease, left breast irradiation, pectus excavatum, prominent contralateral prosthesis and internal mammary chain disease. We discuss the practicalities of such treatment and the advantages over standard breast irradiation techniques. RESULTS Advantages include better conformity of treatment with lowering of dosages to underlying organs at risk, for example ipsilateral lung and heart. There is improved coverage of the planning target volume, including regional nodes, without field junction problems. Planning, quality assurance and treatment delivery are more time consuming than for standard breast irradiation and the low dose 'bath' is increased. CONCLUSIONS The standard radiotherapy tangential technique for breast/chest wall treatments has not significantly changed over many decades, whereas across many other tumour sites there have been great advances in radiotherapy technology. The dosimetric advantages of IMRT are readily apparent from our early experience. The wider spread of the lower dose zone (the low dose 'bath' of radiation) is a potential concern regarding late oncogenesis and methods to minimise such risks should be considered.
منابع مشابه
The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کاملComparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)
Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients. Materials and Methods: Co...
متن کاملA treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation.
PURPOSE AND BACKGROUND Conventional early breast cancer treatment consists of a lumpectomy followed by whole breast radiation therapy. Accelerated partial breast irradiation (APBI) is an investigational approach to post-lumpectomy radiation for early breast cancer. The purpose of this study is to compare four external beam APBI techniques, including tomotherapy, with conventional whole breast i...
متن کاملIs helical tomotherapy-based intensity-modulated radiotherapy feasible and effective in bilateral synchronous breast cancer? A two-center experience.
PURPOSE This study describes the early clinical results and dosimetric parameters of intensity-modulated radiation therapy (IMRT) using a tomotherapy device in patients with primary bilateral synchronous breast cancer (PSBBC). METHODS Fourteen patients with bilateral breast cancer were treated with tomotherapy between January 2011 and October 2014. The treatment planning objectives were to co...
متن کاملDosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical oncology (Royal College of Radiologists (Great Britain))
دوره 21 4 شماره
صفحات -
تاریخ انتشار 2009