Detection of right-to-left shunt with transcranial Doppler is affected by body-positioning.

نویسندگان

  • Georgios Tsivgoulis
  • Vijay K Sharma
  • Andrei V Alexandrov
چکیده

Detection of Right-to-Left Shunt With Transcranial Doppler Is Affected by Body-Positioning To the Editor: We read with great interest the recent study by Caputi et al regarding the postural dependency of right-to-left shunt (RLS) detection using contrast-enhanced transcranial Doppler (TCD).1 After using TCD to detect the bubble-load in 2 different body positions (recumbent and standing) in consecutive RLS-positive patients (confirmed by transthoracic echocardiogram), the authors concluded that the amount of bubbles detected was dependent on body position, with 42% of the study population exhibiting almost a 3-fold increase in the yield of microbubbles in the standing compared to the supine position.1 Our group has previously investigated whether body-positioning may affect the sensitivity of TCD in detecting and grading RLS in patients with ischemic stroke or transient ischemic attacks that were referred to our neurosonology laboratory. As Caputi and colleagues acknowledge, we documented remarkably similar results to their findings.2 More specifically, in our study the change of bodypositioning from the supine (which is the currently recommended position for TCD-screening for RLS according to the International Consensus Criteria developed in Venice3) to sitting upright position increased substantially the microbubble count (from a median of 20 in the supine to a median of 72 in the sitting position) in 42% of our study population. Moreover, we failed to document any changes in blood pressure and heart rate levels during TCD-testing in different body positions, whereas changes in body position followed by additional agitated saline injections were well-tolerated with no adverse events. In addition, if the initial supine Valsalva-aided contrast TCD-testing was negative, all subsequent positions/injections were also negative for RLS. In view of the limited available data as regards the effect of body-positioning on the yield of TCD in screening and grading RLS,1–5 Caputi et al may consider reporting if they recorded any posture-related changes in blood pressure and heart rate or any orthostastic symptoms during the application of their extended TCD protocol. Furthermore, it would be interesting if they were able to detect any cases with negative TCD-testing for RLS in the recumbent position, who were subsequently positive in the standing position. These data may provide useful information concerning whether additional body positions also increase the sensitivity of TCD for detecting RLS in addition to increasing the number of detected microbubbles that affects substantially the grading of the degree of RLS. Finally, we would like to underline that the findings of those 2 recent studies1,2 may have certain clinical applications (avoiding paradoxical embolism during surgery in the sitting position, diagnosing more reliably paradoxical embolism in patients with cryptogenic stroke, screening more effectively for the largely underdiagnosed platypnea orthodeoxia syndrome) as Caputi et al have insightfully noted in the discussion of their results. Additionally, we want to highlight the importance of correctly grading the degree of RLS using contrast TCD, because the studies of Serena et al6 and Anzola et al7 have shown that quantification of RLS on the basis of microbubble count can provide useful information for the likelihood of prevalent ischemic stroke or for the risk of recurrent ischemic stroke respectively. After taking into account the findings of the former 2 studies1,2 and recent reports8,9 that the SpencerLogarithmic-Scale TCD criteria may be more sensitive and specific for diagnosing larger or functional patent foramen ovale, we propose that a prospective multicenter study of testing protocols with different body positions and a revision of commonly accepted procedural and diagnostic criteria to optimize RLS screening with TCD may be warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates

Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...

متن کامل

Results of Transcranial Doppler in Children with Sickle Cell Disease: Correlation between the Time-Averaged Mean of Maximum Velocity and Some Hematological Characteristics

Abstract Background: Transcranial Doppler ultrasonography results have not been previously studied in among Iranian sickle cell anemia patients. The present study was performed to evaluate the pattern of intracranial flow velocities among Iranian children with sickle cell anemia and the hematological parameters that can affect the time-averaged mean of maximum velocity in major intracranial...

متن کامل

Comparison of agitated saline mixed with blood to agitated saline alone in detecting right-to-left shunt during contrast- transcranial Doppler sonography examination.

PURPOSE To evaluate a technique for contrast agent preparation as mixing the patients' blood with agitated saline and to compare it with agitated saline alone in diagnosis of cardiac right-to-left shunt in regard to their sensitivity, time window, and distribution of artificially induced microembolic signals. METHODS Fifty-two patients with stroke who had Transesophageal echocardiography prov...

متن کامل

Comparison of Vertebral Artery and Middle Cerebral Artery Monitoring for Right-to-left Shunt Detection by Contrast-enhanced Transcranial Doppler

Contrast-enhanced transcranial Doppler (c-TCD) is a reliable and reproducible method for right-to-left shunt (RLS) detection, with high sensitivity. Monitoring the middle cerebral artery (MCA) is an optimal choice, yet for patients with insufficient temporal bone windows or severe stenosis of carotid arteries, an alternative should be established. The aim of the present study was to further est...

متن کامل

Methodological parameters influence the detection of right-to-left shunts by contrast transcranial Doppler ultrasonography.

BACKGROUND AND PURPOSE Contrast transcranial Doppler ultrasonography is a new method to detect intracardiac right-to-left shunts, such as the patent foramen ovale. However, the methodology of the procedure varies considerably among investigators. This study was undertaken to assess the influence of methodological parameters on the results of the contrast transcranial Doppler examination in the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 39 11  شماره 

صفحات  -

تاریخ انتشار 2008