Correlation between central venous oxygen saturation and oxygen delivery changes following fluid therapy.
نویسندگان
چکیده
BACKGROUND The rationale for using central venous oxygen saturation (ScvO(2)) in various clinical scenarios is that it reflects the balance between oxygen delivery (DO(2)) and demands. In this study, we evaluated the correlation between ScvO(2) and DO(2) changes (Delta Do(2), DeltaScvO(2)) in patients receiving fluid therapy following coronary surgery. We also correlated the changes of mean arterial pressure (Delta MAP) and central venous pressure (Delta CVP), with Delta DO(2). METHODS Sixty consecutive sedated and mechanically ventilated adult patients, with cardiac index <or=2.3 L/min/m(2) and a pulmonary artery occlusion pressure <or=12 mmHg following coronary surgery, were included. Concomitant hemodynamic parameters, arterial and venous blood gases were measured before (T0) and after (T1) administration of a 500 ml bolus of an isotonic crystalloid solution over 30 min. The correlations between Delta DO(2) and DeltaScvO(2), Delta MAP or Delta CVP were evaluated by linear regression analysis and Pearson test. RESULTS Cardiac index (1.9+/-0.2 vs 2.3+/-0.5 ml/min/m(2)), MAP (83+/-11 vs 94+/-13 mm Hg) and CVP (5.7+/-3 vs 7.1+/-3 mmHg) were significantly higher at T1 compared with T0. The correlation of Delta DO(2) with DeltaScvO(2) was positive, significant (r=0.41; P=0.004) and superior to its correlation with Delta MAP (r=0.30; P=0.01) or Delta CVP (r=0.03; P=0.78). CONCLUSION A significant correlation between ScvO(2) and DO(2) changes was found in patients receiving fluid therapy following coronary surgery. ScvO(2) could be used as an indicator to track DO(2) and to guide volume loading.
منابع مشابه
Lactate and venoarterial carbon dioxide difference/arterial-venous oxygen difference ratio, but not central venous oxygen saturation, predict increase in oxygen consumption in fluid responders.
OBJECTIVES During circulatory failure, the ultimate goal of treatments that increase cardiac output is to reduce tissue hypoxia. This can only occur if oxygen consumption depends on oxygen delivery. We compared the ability of central venous oxygen saturation and markers of anaerobic metabolism to predict whether a fluid-induced increase in oxygen delivery results in an increase in oxygen consum...
متن کاملCritical Assessment of Use of Central Venous Oxygen Saturation as a Mirror of Mixed Venous Oxygen in Severely Ill Cardiac Patients By MELVIN
Bedside catheterization of the right heart with a percutaneously introduced flowdirected catheter was carried out in 24 critically ill patients; 71 determinations of mixed venous oxygen saturation (MVo2) were obtained. A second catheter was inserted either into a central intrathoracic vein or the right atrium for simultaneous sampling of central venous (CVo2) or right atrial (RAo2) oxygen satur...
متن کاملChallenges associated with central venous catheter placement and central venous oxygen saturation monitoring.
Patients with septic shock and respiratory failure often require hemodynamic monitoring in order to guide bedside management. This is particularly true of patients with dialysis-dependent chronic kidney disease, who may be less tolerant of large volume resuscitation than individuals with normal renal function. With the declining use of pulmonary artery catheters and the introduction of early go...
متن کاملCentral venous oxygen saturation: analysis, clinical use and effects on mortality.
AIMS AND OBJECTIVES The aim of this literature review was to provide a clear definition of central venous oxygen saturation (ScvO₂), highlight the differences between ScvO₂ and mixed venous oxygen saturation (SvO₂), show how it can be used clinically and the effect central venous oxygen saturation has on mortality. BACKGROUND Many articles concentrate on the individual aspects of ScvO₂, such ...
متن کاملHigh mixed venous oxygen saturation levels do not exclude fluid responsiveness in critically ill septic patients
INTRODUCTION The aim of this study was to determine whether the degree of fluid responsiveness in critically ill septic patients is related to baseline mixed venous oxygen saturation (SvO2) levels. We also sought to define whether fluid responsiveness would be less likely in the presence of a high SvO2 (>70%). METHODS This observational study was conducted in a 32-bed university hospital medi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta anaesthesiologica Scandinavica
دوره 52 9 شماره
صفحات -
تاریخ انتشار 2008