Effects of hindlimb unweighting on the mechanical and structure properties of the rat abdominal aorta.
نویسندگان
چکیده
Previous studies have shown that hindlimb unweighting of rats, a model of microgravity, reduces evoked contractile tension of peripheral conduit arteries. It has been hypothesized that this diminished contractile tension is the result of alterations in the mechanical properties of these arteries (e.g., active and passive mechanics). Therefore, the purpose of this study was to determine whether the reduced contractile force of the abdominal aorta from 2-wk hindlimb-unweighted (HU) rats results from a mechanical function deficit resulting from structural vascular alterations or material property changes. Aortas were isolated from control (C) and HU rats, and vasoconstrictor responses to norepinephrine (10(-9)-10(-4) M) and AVP (10(-9)-10(-5) M) were tested in vitro. In a second series of tests, the active and passive Cauchy stress-stretch relations were determined by incrementally increasing the uniaxial displacement of the aortic rings. Maximal Cauchy stress in response to norepinephrine and AVP were less in aortic rings from HU rats. The active Cauchy stress-stretch response indicated that, although maximum stress was lower in aortas from HU rats (C, 8.1 +/- 0.2 kPa; HU, 7.0 +/- 0.4 kPa), it was achieved at a similar hoop stretch. There were also no differences in the passive Cauchy stress-stretch response or the gross vascular morphology (e.g., medial cross-sectional area: C, 0.30 +/- 0.02 mm(2); HU, 0.32 +/- 0.01 mm(2)) between groups and no differences in resting or basal vascular tone at the displacement that elicits peak developed tension between groups (resting tension: C, 1.71 +/- 0.06 g; HU, 1.78 +/- 0.14 g). These results indicate that HU does not alter the functional mechanical properties of conduit arteries. However, the significantly lower active Cauchy stress of aortas from HU rats demonstrates a true contractile deficit in these arteries.
منابع مشابه
Study of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction
Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...
متن کاملDifferential vascular cell adhesion molecule-1 expression and superoxide production in simulated microgravity rat vasculature
Exposure to microgravity leads to orthostatic intolerance in astronauts and differential vascular structural and functional adaptations have been implicated in its occurrence. The present study tended to clarify the characteristics of vascular inflammation and oxidative stress in hindlimb unweighting (HU) rat vasculature. Male Sprague-Dawley rats were randomly divided into control (CON) and hin...
متن کاملHindlimb unweighting induces changes in the p38 contractile pathway of the rat abdominal aorta
Summers SM, Hayashi Y, Nguyen SV, Nguyen TM, Purdy RE. Hindlimb unweighting induces changes in the p38 contractile pathway of the rat abdominal aorta. J Appl Physiol 107: 121–127, 2009. First published May 14, 2009; doi:10.1152/japplphysiol.00210.2009.— Hindlimb unweighting (HLU) of rats is a model used to mimic the cephalic fluid shift potentially involved in the orthostatic intolerance experi...
متن کاملHindlimb unweighting induces changes in the p38MAPK contractile pathway of the rat abdominal aorta.
Hindlimb unweighting (HLU) of rats is a model used to mimic the cephalic fluid shift potentially involved in the orthostatic intolerance experienced by astronauts. Certain arteries in these rats exhibit a decreased contractile response to adrenergic agonists. It was shown previously that this may be caused by changes in thick filament regulation (Summers et al., Vascul Pharmacol 48: 208-214, 20...
متن کاملEffect of simulated microgravity on vascular contractility.
Microgravity was simulated in Sprague-Dawley (SD) and Wistar (W) rats by using a tail harness to elevate the hindquarters, producing hindlimb unweighting (HU). After 20 days of HU treatment, blood vessels from both HU and control rats were cut into 3-mm rings and mounted in tissue baths for the measurement of isometric contraction. HU treatment decreased the contractile response to 68 mM K+ in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 94 2 شماره
صفحات -
تاریخ انتشار 2003