Fourier Consistency-Based Motion Estimation in Rotational Angiography
نویسندگان
چکیده
Rotational coronary angiography allows for volumetric imaging but requires cardiac and respiratory motion management to achieve meaningful reconstructions. Novel respiratory motion compensation algorithms based on data consistency conditions are applied directly in projection domain and, therefore, overcome the need for uncompensated reconstructions. Earlier, we combined single-frame background subtraction and epipolar consistency conditions to compensate for respiratory motion. In this paper, we show that background subtraction also enables motion estimation via optimization of novel Fourier consistency conditions. The proposed method is evaluated in a numerical phantom study. Compared to the uncompensated case, we found a reduction in residual rootmean-square error of 89 % when Fourier consistency conditions were used. The results are promising and encourage experiments on clinical data.
منابع مشابه
Motion Estimation in Rotational Angiography with α–Expansion Moves
Rotational coronary angiography allows for 3D reconstruction in interventional guidance of percutaneous coronary interventions. While gated reconstruction is able to account for cardiac motion, residual breathing motion must be compensated for. Epipolar consistency has been shown to accurately extract the craniocaudal displacement of the heart during contraction and breathing. However, optimiza...
متن کاملDynamic Cone Beam Reconstruction Using a New Level Set Formulation
This paper addresses an approach toward tomographic reconstruction from rotational angiography data as it is generated by C-arms in cardiac imaging. Since the rotational acquisition scheme forces a trade-off between consistency of the scene and reasonable baselines, most existing reconstruction techniques fail at recovering the 3D + t scene. We propose a new reconstruction framework based on va...
متن کاملDynamic Cone-Beam Reconstruction Using a Variational Level Set Formulation
Tomographic reconstruction from cone-beam X-ray data is only solved for static objects, e. g. the abdomen. In cardiac imaging, a rotational angiography sequence takes approx. 5 s and therefore spans several heart beats. Since such an acquisition scheme forces a trade-off between consistency of the scene and reasonable angular spacings between camera positions, standard reconstruction techniques...
متن کاملEstimating Continuous 4D Wall Motion of Cerebral Aneurysms from 3D Rotational Angiography
This paper presents a technique to recover dynamic 3D vascular morphology from a single 3D rotational X-ray angiography acquisition. The dynamic morphology corresponding to a canonical cardiac cycle is represented via a 4D B-spline based spatiotemporal deformation. Such deformation is estimated by simultaneously matching the forward projections of a sequence of the temporally deformed 3D refere...
متن کاملEstimation of Translation, Rotation, and Scaling between Noisy Images Using the Fourier--Mellin Transform
In this paper we focus on extended Euclidean registration of a set of noisy images. We provide an appropriate statistical model for this kind of registration problems, and a new criterion based on Fourier-type transforms is proposed to estimate the translation, rotation and scaling parameters to align a set of images. This criterion is a two step procedure which does not require the use of a re...
متن کامل