Evaluation of a new immunoassay for chromogranin A measurement on the Kryptor system

نویسندگان

  • R.H.P. van der Knaap
  • D.J. Kwekkeboom
  • C.R.B. Ramakers
  • Y.B. de Rijke
چکیده

BACKGROUND Chromogranin A (CgA) is a biomarker for neuroendocrine tumors (NETs). The aims of this study were to evaluate differences in measurement between the ThermoFisher Brahms CgA Kryptor assay and the CisBio assay and to investigate the influence of patient covariates. Temperature stability of CgA using both assays was determined. DESIGN AND METHODS 406 patients were analyzed for serum CgA using both assays. We performed a comparison study to determine whether several patient covariates (gender, use of protein pump inhibitors, impaired kidney function, referral department and tumor location) influenced the results. For the stability study, pooled serum samples were aliquoted and stored at different storage temperatures (room temperature, 4 °C and -20 °C) until assayed. In addition, 15 individual samples were evaluated after storage at 4 °C using the Kryptor assay. RESULTS Differences in measured concentrations between the assays were statistically significant. Passing & Bablok fit showed ln Y(Kryptor)=1.05 ln X(CisBio) - 0.20 with a bias of 1.0% after logarithmic transformation. Patient covariates were not associated. Patients׳ sera showed variable stability for CgA in the Kryptor assay at room temperature and 4 °C, whereas the recovery in the CisBio assay was stable at both temperatures. CONCLUSION Differences in measured CgA concentration between the assays could not be explained by the investigated patient covariates. Serum should be stored at -20 °C prior to determination using the Kryptor assay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

The Measurement of Rigidity in Elbow Joint: An Objective Method for the Evaluation of Parkinson's disease

Introduction: One of the most common syndromes in Parkinson's disease (PD) is rigidity. Currently, an index is used to evaluate the level of PD by the clinical measurement of rigidity in the upper extremity. The index uses a subjective method called Unified Parkinson's Disease Rating System (UPDRS). The subjective nature of this method makes the influence of physician in the measurement of rigi...

متن کامل

Efficiency evaluation of wheat farming: a network data envelopment analysis approach

Traditional data envelopment analysis (DEA) models deal with measurement of relative efficiency of decision making units (DMUs) in which multiple-inputs consumed to produce multiple-outputs. One of the drawbacks of these models is neglecting internal processes of each system, which may have intermediate products and/or independent inputs and/or outputs. In this paper some methods which are usab...

متن کامل

Familial dysalbuminemic hyperthyroxinemia: a persistent diagnostic challenge.

1. Barassi A, Pallotti F, Melzi d’Eril GV. Biological variation of procalcitonin in healthy individuals. Clin Chem 2004;50:1878. 2. Assicot M, Gendrel D, Carsin H, Raymond J, Guilbaud J, Bohuon C. High serum procalcitonin concentrations in patients with sepsis and infection. Lancet 1993;341:515–8. 3. Stolz D, Christ-Crain M, Bingisser R, Leuppi J, Miedinger D, Müller C, et al. Antibiotic treatm...

متن کامل

A New Structure for Direct Measurement of Temperature Based on Negative Temperature Coefficient Thermistor and Adaptive Neuro-fuzzy Inference System

Thermistors are very commonly used for narrow temperature-range high-resolution applications, such as in medicine, calorimetry, and near ambient temperature measurements. In particular, Negative Temperature Coefficient (NTC) thermistor is very inexpensive and highly sensitive, whose sensing temperature range and sensitivity are highly limited due to the intrinsic nonlinearity and self-heating p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2015