Vesicle biomechanics in a time-varying magnetic field

نویسندگان

  • Hui Ye
  • Austen Curcuru
چکیده

BACKGROUND Cells exhibit distortion when exposed to a strong electric field, suggesting that the field imposes control over cellular biomechanics. Closed pure lipid bilayer membranes (vesicles) have been widely used for the experimental and theoretical studies of cellular biomechanics under this electrodeformation. An alternative method used to generate an electric field is by electromagnetic induction with a time-varying magnetic field. References reporting the magnetic control of cellular mechanics have recently emerged. However, theoretical analysis of the cellular mechanics under a time-varying magnetic field is inadequate. We developed an analytical theory to investigate the biomechanics of a modeled vesicle under a time-varying magnetic field. Following previous publications and to simplify the calculation, this model treated the inner and suspending media as lossy dielectrics, the membrane thickness set at zero, and the electric resistance of the membrane assumed to be negligible. This work provided the first analytical solutions for the surface charges, electric field, radial pressure, overall translational forces, and rotational torques introduced on a vesicle by the time-varying magnetic field. Frequency responses of these measures were analyzed, particularly the frequency used clinically by transcranial magnetic stimulation (TMS). RESULTS The induced surface charges interacted with the electric field to produce a biomechanical impact upon the vesicle. The distribution of the induced surface charges depended on the orientation of the coil and field frequency. The densities of these charges were trivial at low frequency ranges, but significant at high frequency ranges. The direction of the radial force on the vesicle was dependent on the conductivity ratio between the vesicle and the medium. At relatively low frequencies (<200 KHz), including the frequency used in TMS, the computed radial pressure and translational forces on the vesicle were both negligible. CONCLUSIONS This work provides an analytical framework and insight into factors affecting cellular biomechanics under a time-varying magnetic field. Biological effects of clinical TMS are not likely to occur via alteration of the biomechanics of brain cells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetohydrodynamic Free Convection Flows with Thermal Memory over a Moving Vertical Plate in Porous Medium

The unsteady hydro-magnetic free convection flow with heat transfer of a linearly viscous, incompressible, electrically conducting fluid near a moving vertical plate with the constant heat is investigated. The flow domain is the porous half-space and a magnetic field of a variable direction is applied. The Caputo time-fractional derivative is employed in order to introduce a thermal flux consti...

متن کامل

Does Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?

MRI workers are occupationally exposed to static and time-varying gradient magnetic fields.  While the 24-hour time-averaged exposure to static magnetic fields is about a few mT, the maximum static field strength can be as high as 500 mT during patient setup. Over the past several years, our laboratory has performed extensive experiments on the health effects of exposure of animal models and h...

متن کامل

Kinematic difference between a biological cell and an artificial vesicle in a strong DC electric field – a “shell” membrane model study

Background: Cellular biomechanics can be manipulated by strong electric fields, manifested by the field-induced membrane deformation and migration (galvanotaxis), which significantly impacts normal cellular physiology. Artificial giant vesicles that mimic the phospholipid bilayer of the cell membrane have been used to investigate the membrane biomechanics subjected to electric fields. Under a s...

متن کامل

The Inhibitory Effects of Static Magnetic Field on Escherichia coli from two Different Sources at Short Exposure Time

This study was intended to investigate the effectiveness of static magnetic field on the growth of Escherichia coli (E. coli) provided from two sources, the urine samples of patients with urinary tract infections and the reference strain E. coli ATCC 25922. Bacterial samples in Nutrient Broth were subjected to a range of magnetic intensities (2, 4, 6, 9, 14, 16, 18, and 20 mT) at various exposu...

متن کامل

Effect of Magnetic Field on Seed Germination and Early Growth of Calendula officinalis L.

 In order to study on effect of magnetic field on germination characteristics and early growth of marigold (Calendula officinalis L.) seeds an experiment was carried out in laboratory conditions in Arak University of Iran. Seeds were magnetically exposed to magnetic field strengths, 100 or 200 mT for different periods of time; D1 (control), D2 (1 h), D3 (6 h), D4 (12h), D5 (24 h) and D6 (contin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2015