The measurement of rate of aqueous flow with iodide.
نویسنده
چکیده
Trace amounts of iodide are transported out of the rabbit eye in such a fashion that this union accumulates in the aqueous humor of the anterior chamber exponentially toith time. Iodide is therefore a useful anion for estimating the coefficient of aqueous flow and requires punctures of the anterior chamber only. The method can be used in two eyes of one animal, or with the use of two or more isotopes of iodide, can be applied to a single eye. The iodide methoddemonstrates a floiu coefficient of 1.5 per cent of the anterior chamber per minute in the normal animal. It is reduced by some 45 to 50 per cent following acetazolamide, by 80 to 90 per cent during hypothermia (18 to 20° C), and by an average of 17 per cent on the side of carotid ligation. Topical pilocarpine appears to increase the flow coefficient by an average of 16 per cent and atropine to decrease it by 21 per cent.
منابع مشابه
Normal measurement of peak expiratory Flow rate in the high school children in Babol, north of Iran
Background: Peak Expiratory Flow Rate (PEFR) is recommended as a tool for control of asthma. The purpose of this study was to determine the normal value of PEFR in the healthy high school children in Babol, Iran. Methods: This study was conducted on 470 healthy high school children (285 girls, 185 boys with the age between 14-18 years). For the determination of PEFR we used Mini Wright Peak Flo...
متن کاملNumerical modeling of three-phase flow through a Venturi meter using the LSSVM algorithm
One of the challenging problems in the Oil & Gas industry is accurate and reliable multiphase flow rate measurement in a three-phase flow. Application of methods with minimized uncertainty is required in the industry. Previous developed correlations for two-phase flow are complex and not capable of three-phase flow. Hence phase behavior identification in different conditions to designing and mo...
متن کاملPropionic acid extraction in a microfluidic system: simultaneous effects of channel diameter and fluid flow rate on the flow regime and mass transfer
In this work, extraction of propionic acid from the aqueous phase to the organic phase (1-octanol) was performed in T-junction microchannels and effects of channel diameter and fluid flow rate on the mass transfer characteristics were investigated. The two-phase flow patterns in studied microchannels with 0.4 and 0.8 mm diameters were observed. Weber number and surface-to-volume ratio were ca...
متن کاملبررسی تاثیر غلظت و نرخ جریان ورودی به ستون بستر ثابت بر روی عملکرد جذب زیستی نیکل توسط جلبک قهوهای پروتونه شده Cystoseira indica و مدلسازی نتایج تجربی
Background and Objectives: Biosorption is a new and inexpensive technique in heavy metals removal and recovery from aqueous solutions. In order to evaluate the potential of this method for the removal of nickel ions, biosorption of nickel ions from aqueous solution was studied using Cystoseira indica biomass in a packed bed column. Materials and Methods: The uptake capacity of nickel ions was...
متن کاملSaffron Aqueous Extract Inhibits the Chemically-induced Gastric Cancer Progression in the Wistar Albino Rat
Objective(s): Gastric cancer is the first and second leading cause of cancer related death in Iranian men and women, respectively. Gastric cancer management is based on the surgery, radiotherapy and chemotherapy. In the present study, for the first time, the beneficial effect of saffron (Crocus sativus L.) aqueous extract (SAE) on the 1-Methyl-3-nitro-1-nitrosoguanidine (MNNG)-induced gastric c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology
دوره 1 شماره
صفحات -
تاریخ انتشار 1962