Collateral variations in circle of willis in atherosclerotic population assessed by means of transcranial color-coded duplex ultrasonography.

نویسندگان

  • A W Hoksbergen
  • D A Legemate
  • D T Ubbink
  • M J Jacobs
چکیده

BACKGROUND AND PURPOSE Transcranial color-coded duplex ultrasonography combined with common carotid artery (CCA) compression can be used to assess the collateral function of the circle of Willis. The aim of this study was to assess the unknown fraction of hemodynamic functional anterior and posterior communicating arteries (AcoA and PcoA, respectively) in an atherosclerotic population with no cerebrovascular symptoms. METHODS In 76 patients with a mean age of 61 (35 to 89) years, the blood flow velocity changes in the precommunicating parts (A1 and P1, respectively) of the anterior and posterior cerebral arteries were measured during CCA compression. The AcoA was defined as functional if blood flow was reversed in the ipsilateral A1 and enhanced in the contralateral A1 during CCA compression. The PcoA was defined as functional if the flow velocity in the P1 was enhanced >20% during ipsilateral CCA compression. RESULTS It was possible to assess cross flow through the anterior part of the circle of Willis in 95% of the subjects. Failure of this collateral pathway was caused by a hypofunctional AcoA in 4% and a hypofunctional A1 in 1% of the subjects. Anomalies in the posterior part of the circle of Willis hampering collateral flow from the basilar to the internal carotid artery were found in 45% of the hemispheres. Thirty-eight percent of PcoAs were hypofunctional, and 7% of the posterior cerebral arteries had a persistent fetal anatomy. CONCLUSIONS We found that in subjects with no cerebrovascular symptoms, the anterior collateral pathway of the circle of Willis was nearly always functional. In contrast, the posterior collateral pathway was nonfunctional in almost half of the total number of hemispheres. Comparing these basic data with data from patients with cerebral ischemic disease might further help to elucidate the importance of the collateral capacity of the circle of Willis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Collateral configuration of the circle of Willis: transcranial color-coded duplex ultrasonography and comparison with postmortem anatomy.

BACKGROUND AND PURPOSE The anterior communicating artery (AcoA) and posterior communicating arteries (PcoA) of the circle of Willis provide the main route for collateral blood flow in cases of carotid artery obstruction. Transcranial color-coded duplex ultrasonography (TCCD) allows real-time measurement of the collateral function of the AcoA and PcoA. The primary objective of this study was to ...

متن کامل

Assessment of the collateral function of the circle of Willis: three-dimensional time-of-flight MR angiography compared with transcranial color-coded duplex sonography.

BACKGROUND AND PURPOSE Identification of the intracranial collaterals assists in identifying patients with severe occlusive disease of the internal carotid arteries who are at lower risk of transient ischemic attacks (TIAs) and stroke. We investigated the usefulness of MR angiography in identifying functional collaterals of the circle of Willis. METHODS MR angiography of the circle of Willis ...

متن کامل

Comparison of transcranial power Doppler and contrast-enhanced color-coded sonography in the identification of intracranial arteries.

Power-based transcranial color-coded sonography and contrast-enhanced transcranial color-coded sonography are ultrasonographic techniques that allow improved visualization of vascular structures. The present study was designed to investigate and compare the diagnostic capacity and applicability of both methods in the assessment of intracranial vessels of the circle of Willis (33 patients) and t...

متن کامل

Assessment of intracranial collateral flow by using dynamic arterial spin labeling MRA and transcranial color-coded duplex ultrasound.

BACKGROUND AND PURPOSE To evaluate the potential of a new dynamic MRA sequence (DynAngio) based on arterial spin labeling for the assessment of intracranial collateral flow. METHODS Twelve patients with unilateral internal carotid artery obstruction were investigated. Different patterns of collateral flow were compared between DynAngio, transcranial color-coded duplex ultrasound, and time-of-...

متن کامل

Transcranial color-coded duplex sonography in the evaluation of collateral flow through the circle of Willis.

PURPOSE To determine the sensitivity, specificity, and positive and negative predictive values of transcranial color-coded duplex sonographic (TCCD) evaluation of cross flow through the anterior (ACoA) and posterior (PCoA) communicating arteries in patients with occlusive cerebrovascular disease. METHODS We studied prospectively 132 patients (37 women, 95 men; mean age, 60 years) with stenose...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 31 7  شماره 

صفحات  -

تاریخ انتشار 2000