Comparison of two algorithms for determining beam weights and wedge filters
نویسندگان
چکیده
This article compares two algorithms for determining beam weights and wedge filters for conformal treatment planning. One algorithm, which is based on dose-gradient analysis, provides analytic formulas for determining beam weights, wedge angles, and collimator angles (i.e., wedge orientations) so that the dose distribution is homogeneous in the target volume. The second algorithm is based on the concept of the super-omni wedge (i.e., the arrangement of two pairs of orthogonal nominal wedged beams), numerically optimize beam weights, wedge angles, and collimator angles so that the dose requirements to targets and organs at risk are satisfied to the best. Three clinical cases were tested. For the first case, both algorithms resulted in comparable homogeneous dose distributions in the target volume. For the second case, the second algorithm resulted in much lower doses to the eyes plus a better homogeneous dose distribution in the target volume. For the third case, only the second algorithm was applicable, and the treatment plan it developed met the prescribed requirements. The results show that the first algorithm is better in terms of feasibility, whereas the second is better in terms of applicability and the quality of treatment plans.
منابع مشابه
Determination of an Effective Wedge Angle by Combination of Two Arbitrary Universal Wedge Fields in Radiation Therapy of Cancer Patients with Megavoltage Photon Beams.
Introduction: Wedge filters are commonly used in radiation oncology for eliminating hot spots and creating a uniform dose distribution in optimizing isodose curves in the target volume for clinical aspects. These are some limited standard physical wedges (15°, 30°, 45°, 60°), or creating an arbitrary wedge angle, like motorized wedge or dynamic wedge, ... The new formulation is...
متن کاملCalculation of wedged dose distributions using an analytical method
Introduction: Wedge filters are used in radiotherapy to modify photon beam and improve dose uniformity in the target volume. Determination of wedge dose distribution is important to improve treatment planning accuracy. The utilization of treatment planning software to obtain dose distribution is not always available. In this work an analytical model has been developed to calcu...
متن کاملSmart Antenna Beamforming using LMS Adaptive Filter Algorithm
Adaptive filters are novel kind of filters used in Digital Signal Processing with adjustable weights. The weight adjustment in adaptive filters is done using some special kind of algorithms called as adaptive algorithms. Adaptive filters have a number of applications in various fields like signal processing, communication systems biomedical etc. One of the novel applications of Adaptive filters...
متن کاملAssessment of variation of wedge factor with depth, field size and SSD for Neptun 10PC Linac in Mashhad Imam Reza Hospital
Background: In radiotherapy, wedge filters are used for optimizing the tumor dose distribution in patients. The attenuation in beam intensity due to the presence of wedge filter is compensated by means of a wedge factor measured at the central axis of the beam. The field size, depth and SSD dependence of wedge factor have been assessed for 9MV radiations of Neptun PC linear accelerator. Materia...
متن کاملImproving the Performance of ICA Algorithm for fMRI Simulated Data Analysis Using Temporal and Spatial Filters in the Preprocessing Phase
Introduction: The accuracy of analyzing Functional MRI (fMRI) data is usually decreases in the presence of noise and artifact sources. A common solution in for analyzing fMRI data having high noise is to use suitable preprocessing methods with the aim of data denoising. Some effects of preprocessing methods on the parametric methods such as general linear model (GLM) have previously been evalua...
متن کامل