Computed tomography measurement of glenoid vault version as an alternative measuring method for glenoid version
نویسندگان
چکیده
BACKGROUND The conventional measuring method for glenoid version is greatly influenced by the scapular body shape that varies widely between patients. We postulated that the glenoid vault version could be more useful than the conventional glenoid version in clinical cases. OBJECTIVES The purposes of this study were to compare the values of glenoid version measured with the conventional method to those with the vault method and to investigate the feasibility of the glenoid vault version. METHODS Computed tomography scans of 150 normal shoulders and 150 arthritic shoulders were analyzed. Three-dimensionally corrected slices were reconstructed from the Digital Imaging and Communications in Medicine (DICOM) data, and glenoid version was measured with both the conventional and vault methods. After determining intra- and interrater reliabilities, differences in glenoid version values between the conventional and vault methods were assessed. In the normal shoulder group, side-to-side differences of glenoid version values were also evaluated in both methods. RESULTS Both measuring methods demonstrated high intra- and interrater reliabilities. The normal glenoid had 1.1° ± 3.2° retroversion with the conventional method and 8.9° ± 2.7° retroversion with the vault method. The average glenoid retroversion of arthritic shoulders was 10.8° ± 9.3° measured with the conventional method and 18.2° ± 9.1° with the vault method. The vault method showed significantly larger glenoid retroversion than the conventional method in both normal and arthritic shoulder groups. Both conventional glenoid retroversion and glenoid vault retroversion were significantly larger on dominant sides than on nondominant sides in the normal shoulders. CONCLUSIONS The glenoid vault version could be used as an alternative measuring method for glenoid version with high reliability. In clinical use, the glenoid vault version appears to be more useful than the conventional glenoid version to assess the severity of arthritis and difficulty of glenoid replacement. The glenoid vault is not symmetric, but usually retroverted in both normal and arthritic shoulders.
منابع مشابه
Glenoid Version Measurement when the Medial Scapula Is Not in the Cross-Sectional Imaging Field of View
Introduction: Glenoid version, glenoid surface orientation in the axial plane, has an important role in the passive stabilization of the articular components of the glenohumeral joint. Glenoid shape and version has been associated with glenohumeral instability, arthritis, and rotator cuff tears. Cross-sectional computed tomography (CT) and magnetic resonance (MR) imaging have been demonstrated ...
متن کاملAccuracy of CT-based measurements of glenoid version for total shoulder arthroplasty.
BACKGROUND/HYPOTHESIS The arthritic glenoid is typically in retroversion and restoration to neutral version is recommended. While a method for measurement of glenoid version using axial computed tomography (CT) has been reported and has been widely accepted, its accuracy and reproducibility has not been established. METHODS In 33 patients scheduled for shoulder arthroplasty, glenoid version a...
متن کاملTwo-dimensional glenoid version measurements vary with coronal and sagittal scapular rotation.
BACKGROUND Accurate analysis of osseous glenoid morphology is important in treating glenohumeral arthritis and instability. Two-dimensional computed tomography scans are used to evaluate glenoid alignment. Accuracy of this method is dependent on the angle of axial reconstruction in relation to the position of the scapula. The purpose of this study was to investigate the effect of scapular rotat...
متن کاملGlenoid resurfacing: what are the limits to asymmetric reaming for posterior erosion?
Eccentric posterior glenoid erosion is a common condition in osteoarthritis. No limits have ever been placed on the degree of eccentric erosion that can be corrected while still maintaining sufficient bone stock to implant a glenoid securely. Five cadaveric scapulae were dissected. Posterior glenoid erosion was created to simulate retroversion of 15 degrees or more. A computed tomography (CT) s...
متن کاملImportance of a three-dimensional measure of humeral head subluxation in osteoarthritic shoulders.
HYPOTHESIS During total shoulder arthroplasty (TSA), humeral head subluxation may be difficult to manage. Furthermore, there is a risk for postoperative recurrence of subluxation, affecting the outcome of TSA. An accurate evaluation of the subluxation is necessary to evaluate this risk. Currently, subluxation is measured in 2 dimensions (2D), usually relative to the glenoid face. The goal of th...