Performance of a new, rapid assay for detection of Trichomonas vaginalis.
نویسندگان
چکیده
Trichomonas vaginalis infection is highly prevalent, may have serious health consequence, and is readily treatable. However, screening has been limited by currently available tests, which tend to be insensitive, expensive, or require a delay before results are reported. The XenoStrip-Tv (Xenotope Diagnostics, Inc., San Antonio, Tex.) was evaluated on vaginal swab specimens from 936 women attending sexually transmitted disease clinics in Seattle, Wash. (n = 497), and Birmingham, Ala. (n = 439). T. vaginalis prevalence by culture (InPouch; Biomed) was 8.7% in Seattle and 21.0% in Birmingham. Compared to culture, the XenoStrip assay in Seattle was 76.7% (95% confidence interval [95% CI] = 61.4 to 88.2) sensitive and 99.8% (95% CI = 98.8 to 99.9) specific, and in Birmingham it was 79.4% (95% CI = 69.6 to 87.1) sensitive and 97.1% (95% CI = 94.8 to 98.6) specific. The positive predictive values were 97.1% in Seattle and 87.9% in Birmingham; the negative predictive values were 97.8 and 94.7%, respectively. Rapid test performance did not vary by vaginal symptoms or by the presence of other vaginal or cervical syndromes or infections. The sensitivity did vary by day of culture-positive result, with a 71% decline in XenoStrip sensitivity for every additional day delay until T. vaginalis was first detected in cultures (odds ratio = 0.29, 95% CI = 0.18 to 0.49). The rapid assay was more sensitive than wet preparation microscopy (78.5% versus 72.4% [P = 0.04]) but was less specific (98.6% versus 100% [P = 0.001]). The XenoStrip rapid assay is well suited for use in settings with a moderately high prevalence of T. vaginalis infection, particularly when microscopy is not practical.
منابع مشابه
Use of an immunochromatographic assay for rapid detection of Trichomonas vaginalis in vaginal specimens.
Trichomonas vaginalis infection is estimated to be the most widely prevalent nonviral sexually transmitted infection in the world. Wet-mount microscopy is the most common diagnostic method, although it is less sensitive than culture. The OSOM Trichomonas Rapid Test (Genzyme Diagnostics, Cambridge, Mass.) (referred to here as OSOM) is a new point-of-care diagnostic assay for T. vaginalis that us...
متن کاملUse of the Roche LightCycler instrument in a real-time PCR for Trichomonas vaginalis in urine samples from females and males.
Trichomonas vaginalis is the agent of a highly prevalent sexually transmitted infection (STI) that can result in vaginitis, urethritis, and preterm birth. Traditional methods of diagnosis, including wet preparation, can be unreliable. In this study, we describe the adaptation of an existing PCR method for specific detection of T. vaginalis DNA into a rapid real-time PCR assay based on fluoresce...
متن کاملLoop-mediated isothermal amplification (LAMP) assay for the rapid detection of the sexually-transmitted parasite, Trichomonas vaginalis.
A loop-mediated isothermal amplification (LAMP) assay was developed to detect the sexually-transmitted parasite, Trichomonas vaginalis in vaginal swabs. The presence of T. vaginalis was detected from 121 female sex workers attending a social hygiene clinic in Balibago, Angeles City, Pampanga, Philippines using culture, polymerase chain reaction (PCR), and the developed LAMP assay. The high anal...
متن کاملDetection of Trichomonas vaginalis in vaginal specimens by direct immunofluorescence assay.
Vaginal discharge specimens from 105 women were examined by wet mount, culture, and a new direct immunofluorescence assay to detect Trichomonas vaginalis. The organism was detected by culture in 31 patients, by direct immunofluorescence in 26 patients, and by wet mount in 21 patients.
متن کاملRapid assay for immunological detection of Trichomonas vaginalis.
Trichomoniasis is a common sexually transmitted disease with an estimated incidence of 4 million to 8 million cases a year in the United States. The most commonly used method of diagnosis is a direct microscopic observation (wet mount) of vaginal secretions and, although both rapid and inexpensive, the sensitivity of this technique is generally 50 to 70%. We developed an indirect enzyme-linked ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 42 7 شماره
صفحات -
تاریخ انتشار 2004