Comparison of platelet storage in PL146 and PL732 plastic packs: preliminary in vitro studies.

نویسندگان

  • D R Edwards
  • C C Entwistle
چکیده

This paper is a preliminary report of in vitro studies comparing platelet storage in the new polyolefin PL732 packs with the present polyvinyl PL146 packs. The parameters used to assess platelet viability in these studies were the recovery from the hypotonic stress test (HST) and the pH. The effect of the mass of concentrate was assessed by preparing 20 g, 35 g and 50 g packs. The method of agitation was tested comparing a vertical rotator with a flat-bed, rocking agitator. In all the subgroups the PL732 packs fared better than the PL146 packs in terms of HST recovery and pH. The 35 g and 50 g packs were statistically inseparable but the 20 g packs were significantly worse both in PL732 and PL146. The vertical rotator augmented the beneficial effects of the PL732 plastic especially in terms of pH. The 35 g and 50 g packs in PL732 on a vertical rotator gave results after 5 days storage at 22 degrees C which were vastly superior (p less than or equal to 0.001) to the 35 g and 50 g packs in PL146 after only three days storage. Thus it would appear that the use of PL732 packs might enable the storage life of platelet concentrates to be increased to five days. Further in vivo studies are to be undertaken to ensure these in vitro improvements benefit the patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of the plasticizer di(2-ethylhexyl)phthalate on red cell deformability.

Red cell concentrates (RCC) are stored for 35 to 42 days in plastic containers manufactured with the liquid plasticizer di(2-ethylhexyl)phthalate (DEHP). DEHP leaches from the polyvinylchloride (PVC) plastic bag, then binds to and stabilizes the RC membrane. This study was undertaken to determine the deformability of the RC membrane using an osmotic gradient ektacytometer and to relate these me...

متن کامل

تاثیر فیلتراسیون پیش از ذخیره کردن بر فعال شدن پلاکت‌ها در فراورده‌های پلاکتی

 Preparation conditions and platelet storage for transfusion may cause platelet activation, which contributes to decreased ability of stored platelet to function and survive in vivo after transfusion compared with that seen with freshly prepared platelets. Using flowcytometry, we investigated platelet membrane expression of CD62P, CD63 in platelet stored for up to 3 days under standard blood ba...

متن کامل

Evaluation of microRNAs; mir223, mir222 and mir92a levels in the Platelet-derived microparticles in the Platelet concentrates produced by Platelet Rich Plasma method during storage

Abstract Background and Objectives Platelets release microparticles containing cellular components, including microRNAs, during storage. Assessment of these microRNAs is one of the markers for evaluation of platelet storage lesions. The aim of the present study was to evaluate the level of changes in the expression of mir-223, mir-92a and mir-222 during storage in platelets prepared by platele...

متن کامل

Flow Cytometric Measurement of CD41/CD61 and CD42b Platelet Receptors and Clotting Assay of Platelet Factor 3 During Long Term-Storage of Platelet Concentrates

Background: The purpose of the present in vitro study was to evaluate the effect of long term storage of conventional platelet concentrates (PCs) on major platelet receptors CD42b and CD41/CD61 by flow cytometry method and also measuring the overall platelet procoagulant activity status using platelet factor 3 (PF3) assay. Materials and Methods: Six random units of conventional platelet conce...

متن کامل

An Overview on Platelet-derived Microparticles in Platelet Concentrates: blood collection, method preparation and storage

Preparations of platelet concentrates (PCs) that are stored under blood bank conditions and used for transfusion purposes, appear to be enriched in platelet derived-microparticles (PMPs) with high coagulant activity that may change platelet efficacy and safety issues. High shear stress could cause shedding of PMPs from the platelet plasma membrane, platelet aggregation, and activation of the co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 35 12  شماره 

صفحات  -

تاریخ انتشار 1982