White-light channeled imaging polarimeter using broadband polarization gratings.

نویسندگان

  • Michael W Kudenov
  • Michael J Escuti
  • Eustace L Dereniak
  • Kazuhiko Oka
چکیده

A white-light snapshot channeled linear imaging (CLI) polarimeter is demonstrated by utilizing polarization gratings (PGs). The CLI polarimeter is capable of measuring the two-dimensional distribution of the linear Stokes polarization parameters by incorporating two identical PGs, in series, along the optical axis. In this configuration, the general optical shearing functionality of a uniaxial crystal-based Savart plate is realized. However, unlike a Savart plate, the diffractive nature of the PGs creates a linear dependence of the shear versus wavelength, thus providing broadband functionality. Consequently, by incorporating the PG-based Savart plate into a Savart plate channeled imaging polarimeter, white-light interference fringes can be generated. This enables polarimetric image data to be acquired at shorter exposure times in daylight conditions, making it more appealing over the quasi-monochromatic channeled imaging polarimeters previously described in the literature. Furthermore, the PG-based device offers significantly more compactness, field of view, optical simplicity, and vibration insensitivity than previously described white-light CLI polarimeters based on Sagnac interferometers. Included in this paper are theoretical descriptions of the linear (S(0), S(1), and S(2)) and complete (S(0), S(1), S(2), and S(3)) channeled Stokes imaging polarimeters. Additionally, descriptions of our calibration procedures and our experimental proof of concept CLI system are provided. These are followed by laboratory and outdoor polarimetric measurements of S(0), S(1), and S(2).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Snapshot imaging Mueller matrix polarimeter using polarization gratings.

A snapshot imaging Mueller matrix polarimeter (SIMMP) is theoretically described and empirically demonstrated through simulation. Spatial polarization fringes are localized onto a sample by incorporating polarization gratings (PGs) into a polarization generator module. These fringes modulate the Mueller matrix (MM) components of the sample, which are subsequently isolated with PGs in an analyze...

متن کامل

Mueller Matrix Imaging Polarimeter for UV Metrology

The University of Arizona Polarization Laboratory with support from the Jet Propulsion Laboratory (JPL) has assembled and is currently calibrating a UV Mueller matrix imaging polarmeter (UV-MMIP). The desire for more accurate polarimetric and radiometric sensors drives the need for stringent polarization requirements and the ability to more precisely measure system and component polarization be...

متن کامل

Broadband wide-angle polarization converter for LCD backlight.

A novel polarization converter using reflective metallic gratings and a polarization beam splitter is introduced for LCD backlight illumination. These two optical elements form a polarization rotation resonator. Broadband and high optical efficiency of polarization conversion in the visible region is achieved through the resonance of the refracted light and the surface plasmon wave in metallic ...

متن کامل

Channeled spectropolarimetry using a coherent white-light continuum.

We carry out polarization measurements using a coherent white-light continuum as a light source for channeled spectropolarimetry. The white-light continuum, whose spectrum ranges from the UV to the IR region, is generated in Kr gas by a terawatt femtosecond laser system. The complete set of Stokes parameters from 450-700 nm are reconstructed from one spectral measurement. Also, the effectivenes...

متن کامل

Snapshot retinal imaging Mueller matrix polarimeter

Early diagnosis of glaucoma, which is a leading cause for visual impairment, is critical for successful treatment. It has been shown that Imaging polarimetry has advantages in early detection of structural changes in the retina. Here, we theoretically and experimentally present a snapshot Mueller Matrix Polarimeter fundus camera, which has the potential to record the polarization-altering chara...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 50 15  شماره 

صفحات  -

تاریخ انتشار 2011