Assessment of spatial uncertainties in the radiotherapy process with the Novalis system.
نویسندگان
چکیده
PURPOSE The purpose of this study was to evaluate the accuracy of a new version of the ExacTrac X-ray (ETX) system with statistical analysis retrospectively in order to determine the tolerance of systematic components of spatial uncertainties with the Novalis system. METHODS AND MATERIALS Three factors of geometrical accuracy related to the ETX system were evaluated by phantom studies. First, location dependency of the detection ability of the infrared system was evaluated. Second, accuracy of the automated calculation by the image fusion algorithm in the patient registration software was evaluated. Third, deviation of the coordinate scale between the ETX isocenter and the mechanical isocenter was evaluated. From the values of these examinations and clinical experiences, the total spatial uncertainty with the Novalis system was evaluated. RESULTS As to the location dependency of the detection ability of the infrared system, the detection errors between the actual position and the detected position were 1% in translation shift and 0.1 degrees in rotational angle, respectively. As to the accuracy of patient verification software, the repeatability and the coincidence of the calculation value by image fusion were good when the contrast of the X-ray image was high. The deviation of coordinates between the ETX isocenter and the mechanical isocenter was 0.313 +/- 0.024 mm, in a suitable procedure. CONCLUSIONS The spatial uncertainty will be less than 2 mm when suitable treatment planning, optimal patient setup, and daily quality assurance for the Novalis system are achieved in the routine workload.
منابع مشابه
Spatial Assessment of Regional Environmental Vulnerability for Environmental Planning in the Eastern Region of Urmia Lake
Environment, development and sustainability are the three significant issues of worldwide concern. Environmental vulnerability and assessment of natural and anthropogenic activities impacts represent a comprehensive evaluation approach. The main purpose of this study is to present a comprehensive and novel framework in order to environmental vulnerability assessment using by spatial data a...
متن کاملA spatial decision support system for prioritizing 22 Districts of Tehran for construction of multiplex buildings
A multiplex is a kind of urban cultural facilities which not only has several different rooms for showing films, but also provides other services such as a wide range of food and drink stores and free/easy available parking. Multiplexes have significant cultural, economic and social characteristics. Given the importance and advantages of multiplexes, several multiplex buildings have been built ...
متن کاملInvestigation of the Spatial Resolution of MR-Based Polymer Gel Dosimetry versus Film Densitometry using Dose Modulation Transfer Function
Introduction: The conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. Although the polymer gel dosimetry method based on magnetic resonance imaging (MRI) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...
متن کاملSimulational study of a dosimetric comparison between a Gamma Knife treatment plan and an intensity-modulated radiotherapy plan for skull base tumors
Fractionated stereotactic radiotherapy (SRT) is performed with a linear accelerator-based system such as Novalis. Recently, Gamma Knife Perfexion (PFX) featured the Extend system with relocatable fixation devices available for SRT. In this study, the dosimetric results of these two modalities were compared from the viewpoint of conformity, heterogeneity and gradient in target covering. A total ...
متن کاملA New Extended Analytical Hierarchy Process Technique with Incomplete Interval-valued Information for Risk Assessment in IT Outsourcing
Information technology (IT) outsourcing has been recognized as a new methodology in many organizations. Yet making an appropriate decision with regard to selection and use of these methodologies may impose uncertainties and risks. Estimating the occurrence probability of risks and their impacts organizations goals may reduce their threats. In this study, an extended analytical hierarchical proc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- International journal of radiation oncology, biology, physics
دوره 75 2 شماره
صفحات -
تاریخ انتشار 2009