VCO2 calorimetry is a convenient method for improved assessment of energy expenditure in the intensive care unit

نویسندگان

  • Ulrike Pielmeier
  • Steen Andreassen
چکیده

In their interesting article, Stapel et al. [1] suggested the use of carbon dioxide production (VCO2) calorimetry with energy expenditure (EE; kcal/day), calculated as 8.19 × VCO2 (ml/min), where VCO2 is provided by the built-in capnometer of the mechanical ventilator. This calculation on average overestimated EE by 7.7 % compared to indirect calorimetry (IC) with a standard deviation (SD) of ±8.4 %. This is within the ±10 % limits of acceptance used in many studies [2] and, more importantly, is an improvement relative to calculation of EE by predictive equations from the patient’s anthropometric data. The equation used by Stapel et al. incorporated a cohort respiratory quotient (RQ) of 0.86. In his commentary, Pierre Singer [3] questions the usability of VCO2 for assessing EE in critically ill patients for three reasons: 1) the concept involves complicated mathematics; 2) calculation of RQ from the patient’s nutrition is complicated and uncertain; and 3) this invalidates the use of VCO2 calorimetry in the critically ill patient. We disagree with the first reason. Multiplying VCO2 by 8.19 is not complicated. We agree with the second reason. We unexpectedly saw significantly lower RQs in patients on a glucose-only diet compared with patients on enteral nutrition, such that individual RQ estimates calculated from the nutrition would have been inaccurate [4]. This does not imply that we agree with the third reason. In our sensitivity analysis we showed that changing our mean cohort RQ of 0.81 to 0.76, which is the lower end of the published range, only increased the VCO2 calorimetry estimates of EE by 6 %, while increasing RQ to the upper end of the published range, RQ = 0.89, reduced estimated EE by 8 %. We recommended choosing a value of RQ = 0.85. With that choice, VCO2 calorimetry on average underestimated EE by 4 %, with an SD of 3 %, relative to EE estimated by IC [4], well within the ±10 % limits of acceptance. Our findings agree well with those by Stapel et al. and our conclusion is that VCO2 calorimetry is both easy and usable as a method for assessing EE for any cohort RQ within the published range (0.76–0.89). The question remains whether VCO2 measured by builtin capnographs in various ventilators is sufficiently accurate. Stapel et al. found a 6.6 % systematic overestimation of VCO2 with their ventilator (SERVO-i; Maquet), compared to the gold standard (Deltatrac II; Datex). This is promising, but data are needed for other built-in capnographs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring energy expenditure in the intensive care unit: a comparison of indirect calorimetry by E-sCOVX and Quark RMR with Deltatrac II in mechanically ventilated critically ill patients.

BACKGROUND Indirect calorimetry allows the determination of energy expenditure in critically ill patients by measuring oxygen consumption (VO2) and carbon dioxide production (VCO2). Recent studies have demonstrated variable performance of "breath-by-breath" instruments compared to mixing chamber technology. The aim of this study was to validate two modern devices (E-sCOVX and Quark RMR) against...

متن کامل

Energy expenditure in critically ill patients estimated by population-based equations, indirect calorimetry and CO2-based indirect calorimetry

BACKGROUND Indirect calorimetry (IC) is the reference method for measurement of energy expenditure (EE) in mechanically ventilated critically ill patients. When IC is unavailable, EE can be calculated by predictive equations or by VCO2-based calorimetry. This study compares the bias, quality and accuracy of these methods. METHODS EE was determined by IC over a 30-min period in patients from a...

متن کامل

VCO2 calorimetry: stop tossing stones, it’s time for building!

We followed with interest the discussion [1, 2] fueled by the study of Stapel et al. [3] who reported fairly accurate assessment of energy expenditure (EE) in critically ill patients based on ventilator-derived carbon dioxide production (VCO2). The proposed technique is elegant and valid but has inherent limitations. It is applicable in patients who are in one way or another ventilator-dependen...

متن کامل

Validation of a predictive method for an accurate assessment of resting energy expenditure in medical mechanically ventilated patients.

OBJECTIVE Use comparison with indirect calorimetry to confirm the ability of our previously described equation to predict resting energy expenditure in mechanically ventilated patients. DESIGN Prospective, validation study. SETTING Eighteen-bed, medical intensive care unit at a teaching hospital. PATIENTS All adult patients intubated >24 hrs were assessed for eligibility. Exclusion criter...

متن کامل

Comparison of measured versus predicted energy requirements in critically ill cancer patients.

BACKGROUND Accurate determination of caloric requirements is essential to avoid feeding-associated complications in critically ill patients. METHODS In critically ill cancer patients we compared the measured and estimated resting energy expenditures. All patients admitted to the oncology intensive care unit between March 2004 and July 2005 were considered for inclusion. For those patients enr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2016