Effect of Vascular Access Site Choice on Radiation Exposure During Coronary Angiography: The REVERE Trial (Randomized Evaluation of Vascular Entry Site and Radiation Exposure).

نویسندگان

  • Samir B Pancholy
  • Pankaj Joshi
  • Sanjay Shah
  • Sunil V Rao
  • Olivier F Bertrand
  • Tejas M Patel
چکیده

OBJECTIVES This study sought to perform a randomized noninferiority trial of radiation exposure during cardiac catheterization comparing femoral access (FA) with left radial access (LRA) and right radial access (RRA). BACKGROUND Increased radiation exposure with radial approach compared with femoral approach remains a controversial issue. METHODS This study randomized 1,493 patients undergoing cardiac catheterization at a tertiary care center to FA, LRA, and RRA in a 1:1:1 fashion. The primary endpoint was air kerma. The secondary endpoints included dose-area product, fluoroscopy time and operator dose per procedure, number of cineangiograms, and number of catheters. RESULTS Baseline and procedural characteristics were similar among groups. No significant differences were observed in air kerma (medians: FA: 421 mGy [interquartile range (IQR): 337 to 574 mGy], LRA: 454 mGy [IQR: 331 to 643 mGy], and RRA: 483 mGy [IQR: 382 to 592 mGy], p = 0.146), dose-area product (medians: FA: 25.5 Gy cm(2) [IQR: 19.6 to 34.5 Gy cm(2)], LRA: 26.6 Gy cm(2) [IQR: 19.5 to 37.5 Gy cm(2)], and RRA: 27.7 Gy cm(2) [IQR: 21.9 to 34.4 Gy cm(2)], p = 0.40), or fluoroscopy time (medians: FA: 1.3 min [IQR: 1.0 to 1.7 min], LRA: 1.3 min [IQR: 1.0 to 1.7 min], and RRA: 1.32 min [IQR: 1.0 to 1.7 min], p = 0.19) among the 3 access sites. Median operator exposure was higher in the LRA group (3 mrem [IQR: 2 to 5 mrem], p = 0.001 vs. FA, and p = 0.0001 vs. RRA) compared with the FA (2 mrem [IQR: 2 to 4 mrem] and RRA groups (3 mrem [IQR: 2 to 5 mrem]). CONCLUSIONS Radiation exposure to patients was similar during diagnostic coronary angiography with FA, RRA, and LRA. However, LRA was associated with significantly higher operator radiation exposure than were FA and RRA procedures. (Randomized Evaluation of Vascular Entry Site and Radiation Exposure [REVERE]; NCT01677481).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Heparin Administration during Coronary Angiography on Vascular or Peripheral Complications: A Single-Blind Randomized Controlled Clinical Trial

Background: Coronary angiography consists of the selective injection of contrast agents in coronary arteries. Optimal strategy for heparin administration during coronary angiography has yet to be determined. We assessed the effect of heparin administration during coronary angiography on vascular, hemorrhagic, and ischemic complications.Methods: Five hundred candiates for diagnostic coronary ang...

متن کامل

Effect of combination of alcohol and Betadine on the severity of inflammation in the vascular access site in hemodialysis patients

Background: Inflammation in the vascular access site results in infection, which is the second leading cause of death in hemodialysis patients. However, there is no specific protocol available for sterilization before vascular access in such patients. Aim: to determine the effect of the combination of alcohol and Betadine on the severity of inflammation in the vascular access site in hemodialys...

متن کامل

Evaluation of Iridium_192 radioisotope dosimeter calculations for vascular Brachiotherapy

Introduction: One of the most effective means for treatment of coronary arteries cramp (CHD) is coronary intravascular Brachiotherapy. In this study, with use of MCNP code, in order to invastigating the score of ditribution of absorbed dose, drope in dose, and simulation mean, radiation doses around iridium_192 radioactive has been done.   Materials and Methods:</str...

متن کامل

Evaluation of Patients’ Exposure during Angiography and Angioplasty Procedures in the Angiography Department of Shahid Madani Hospital in Tabriz

Introduction: Coronary angiography and angioplasty procedures lead to significant radiation exposure of patients. In the current study, the average radiation dose to patients during angiography in the Angiography Department of Shahid-Madani Hospital was determined. Materials and Methods: An image intensifier based angiography unit (Philips BH 3000) was used for angiography procedures. The accur...

متن کامل

Comparison of the effect of rinsing the vascular access site for hemodialysis with Betadine scrub and soap by patient on the frequency and onset of local inflammation and infection

Background: Despite the implementation of nursing measures in disinfecting the ​​vascular access site for hemodialysis, this area is responsible for 23 to 73 percent of bacteremias occurring in these patients. Participation of the patients in washing this area may be helpful. Aim: this study was conducted to determine and compare the effect of washing vascular access site for hemodialysis with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 8 9  شماره 

صفحات  -

تاریخ انتشار 2015