Diagnostic Accuracy of the PURE-LAMP Test for Pulmonary Tuberculosis at the County-Level Laboratory in China

نویسندگان

  • Xichao Ou
  • Qiang Li
  • Hui Xia
  • Yu Pang
  • Shengfen Wang
  • Bing Zhao
  • Yuanyuan Song
  • Yang Zhou
  • Yang Zheng
  • Zhijian Zhang
  • Zhiying Zhang
  • Junchen Li
  • Haiyan Dong
  • Jack Zhang
  • Kai Man Kam
  • Junying Chi
  • Shitong Huan
  • Daniel P. Chin
  • Yanlin Zhao
چکیده

BACKGROUND Early and effective detection of Mycobacterium tuberculosis (MTB), particularly in smear-negative tuberculosis (TB), is a priority for global TB control. Loop-mediated isothermal amplification with a procedure for ultra rapid DNA extraction (PURE-LAMP) can detect TB in sputum samples rapidly and with high sensitivity and specificity. However, the PURE-LAMP test has not been effectively evaluated, especially in resource-limited laboratories. In this study, we evaluated the performance of the PURE-LAMP test for TB detection in TB suspects from two county-level TB dispensaries in China. METHODOLOGY/PRINCIPAL FINDINGS From April 2011 to February 2012, patients with suspected TB were continuously enrolled from two county-level TB laboratories in China. Three sputum samples (spot, night, and morning sputum) were collected from each recruited patient. Detection of MTB by PURE-LAMP was compared to a reference standard L-J culture. The results showed that the sensitivity of the PURE-LAMP test based on spot sputum for MTB detection was 70.67%, while the sensitivity of the PURE-LAMP test based on spot sputum for MTB detection in smear positive and culture positive patients and smear negative and culture positive patients was 92.12% and 53.81%, respectively. The specificity of PURE-LAMP based on spot sputum for MTB detection was 98.32%. The sensitivity and specificity of the PURE-LAMP test based on three sputa combination for MTB detection was 88.80% and 96.86%, respectively. The results also showed that the PURE-LAMP test had a significantly lower contamination rate than did solid culture. CONCLUSIONS/SIGNIFICANCE The study suggested that, in peripheral-level TB laboratories in China, the PURE-LAMP test showed high sensitivity and specificity for TB detection in TB suspects, making it a more effective, rapid, and safe method worthy of broader use in the future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis of Pulmonary Tuberculosis Using Artificial Intelligence (Naive Bayes Algorithm)

Background and Aim: Despite the implementation of effective preventive and therapeutic programs, no significant success has been achieved in the reduction of tuberculosis. One of the reasons is the delay in diagnosis. Therefore, the creation of a diagnostic aid system can help to diagnose early Tuberculosis. The purpose of this research was to evaluate the role of the Naive Bayes algorithm as a...

متن کامل

مقایسه تظاهرات بالینی، آزمایشگاهی و رادیولوژیک سل ریوی میان سالمندان و جوانان

  Background : Atypical clinical manifestations and radiologic images of pulmonary tuberculosis are common in elderly. To investigate the differences in the clinical, radiologic and laboratory features of pulmonary and pleural tuberculosis in older patients, as compared to younger patients.   Methods: The medical records of patients with documented pulmonary tuberculosis in Rasoul-e-Akram hospi...

متن کامل

A multicenter study of cross-priming amplification for tuberculosis diagnosis at peripheral level in China.

Cross-Priming Amplification (CPA) has been shown to rapidly and effectively detect Mycobacterium tuberculosis (MTB) in sputum samples under isothermal conditions. However, no performance data exist from peripheral-level tuberculosis (TB) clinics in tuberculosis-endemic countries. We conducted a clinical trial at four county-level TB clinics in China to evaluate the effectiveness of the CPA assa...

متن کامل

The Impact of Treatment on Serum Level of Procalcitonin in Patients with Active Pulmonary Tuberculosis

Introduction: About one third of the world's population is infected with tuberculosis (TB) and each year, about 1.5 to 2 million people die from TB. Procalcitonin (PCT) is an inflammatory marker that its level has variable Materials and Methods: This conducted on patients with pulmonary TB. Data were collected using a check list. The serum level of PCT was measured by ELISA test at the beginnin...

متن کامل

Nos2 deficiency enhances carbon tetrachloride-induced liver injury in aged mice

Objective(s): As a multifunctional molecule, NO has different effects on liver injury. The present work aimed to investigate the effects of Nos2 knockout (KO) on acute liver injury in aged mice treated with carbon tetrachloride (CCl4). Materials and Methods: The acute liver injury model was produced by CCl4 at 10 ml/kg body weight in 24-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014