Comparing Autorefractors for Measurement of Accommodation.

نویسندگان

  • Mikel Aldaba
  • Selena Gómez-López
  • Meritxell Vilaseca
  • Jaume Pujol
  • Montserrat Arjona
چکیده

PURPOSE To compare the static and dynamic accommodative responses measured with the WAM-5500 and the PowerRef-II autorefractors. METHODS The dynamic and static monocular accommodative responses were measured with the WAM-5500 and the PowerRef-II instruments in 30 pre-presbyopic patients (23.66 [±3.19] years). The spherical equivalent was measured at 0.00, 2.50, and 5.00 diopters (D) of accommodative stimulation for the static measurements. The subjective refraction was also determined. Dynamic accommodation was measured for abrupt changes of stimulus vergence of 2.00 D. Mean and peak velocities of accommodation and disaccommodation were evaluated. For the PowerRef-II, dynamic measurements were calculated for sampling frequencies of 5 and 25 Hz. RESULTS For far distance static results, the differences between subjective and WAM-5500 measurements were 0.07 (±0.21) D (p = 0.093) and those between subjective and PowerRef-II measurements were 0.70 (±0.47) D (p = 0.001). The difference in the response measured with both instruments was 0.08 (±0.32) D (p = 0.194) for 2.50 D and -0.32 (±0.48) D (p = 0.001) for 5.00 D of stimulation. For the dynamic mode, the PowerRef-II at 25 Hz measured faster mean and peak velocities of accommodation and disaccommodation than the WAM-5500, with statistically significant (p < 0.05) differences of 0.68 (±1.01), 0.67 (±0.98), 1.26 (±1.19), and 1.42 (±1.53) D/s, respectively. With a sampling frequency of 5 Hz for the PowerRef-II, these differences, which were statistically significant (p < 0.05), were reduced to 0.52 (±0.90), 0.49 (±0.91), 0.83 (±1.07), and 0.83 (±1.31) D/s, respectively. CONCLUSIONS There is good agreement between subjective refraction and WAM-5500 measurements. In contrast, the PowerRef-II produced more hyperopic results. There were no differences among instruments at 2.50 D of static stimulation; however, differences were found at 5.00 D. In the dynamic measurements, the PowerRef-II measured faster velocities, partly attributed to the difference in the sampling frequency.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical evaluation of refraction using a handheld wavefront autorefractor in young and adult patients.

PURPOSE To determine the accuracy of measurement by the SureSight autorefractor (software version 2.0) and the influence of accommodation. SETTING Pediatric Section, Department of Ophthalmology, University of Hamburg, Hamburg, Germany. METHODS In a series of comparative measurements, autorefractor readings were compared with cycloplegic retinoscopy in 195 eyes of 108 patients (1 to 81 years...

متن کامل

Objective accommodation measurement with the Grand Seiko and Hartinger coincidence refractometer.

PURPOSE Subjective push-up tests and dynamic retinoscopy are standard clinical accommodation tests. These are inadequate for assessing if accommodation can be restored in presbyopes. Commercially available clinical autorefractors offer potentially reliable methods for objective accommodation measurement. This study evaluated accuracy and reliability of the Grand Seiko WR-5100K autorefractor for...

متن کامل

A comparison of autorefraction and subjective refraction with and without cycloplegia in primary school children.

PURPOSE To evaluate the accuracy of autorefraction using three autorefractors comparing to subjective refraction in diagnosing refractive error in children. DESIGN A cross-sectional study. METHODS setting: Community based study. study population: 117 children sampled from primary schools. procedures: All subjects underwent autorefraction using three auto refractors and subjective refraction...

متن کامل

Objective accommodative amplitude and dynamics with the 1CU accommodative intraocular lens.

PURPOSE To compare the objective accommodative amplitude and dynamics of eyes implanted with the one-compartment-unit (1CU; HumanOptics AG, Erlangen, Germany) accommodative intraocular lenses (IOLs) with that measured subjectively. METHODS Twenty eyes with a 1CU accommodative IOL implanted were refracted and distance and near acuity measured with a logMAR (logarithm of the minimum angle of re...

متن کامل

Development of an Accommodation-Dependent Eye Model and Studying the Effects of Accommodation on Electron and Proton Dose Conversion Coefficients

Introduction International Commission on Radiological Protection (ICRP) has provided a comprehensive discussion on threshold dose for radiation-induced cataract in ICRP publication 116. Accordingly, various parts of the eye lens have different radio-sensitivities. Recently, some studies have been performed to develop a realistic eye model with the aim of providing accurate estimation of fluence...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optometry and vision science : official publication of the American Academy of Optometry

دوره 92 10  شماره 

صفحات  -

تاریخ انتشار 2015