Gaussian beam deconvolution in optical coherence tomography
نویسندگان
چکیده
Optical coherence tomography (OCT) is an emerging, high-resolution near-infrared imaging and microscopy technique. The axial and transverse resolutions in OCT can each be analyzed independently, with the axial resolution inversely proportional to the spectral bandwidth of the optical source and the transverse resolution defined by standard Gaussian beam optics. While high numerical-aperture objectives are preferred to improve the transverse resolution, the reduced confocal parameter limits the depth-ranging capabilities of OCT and more complex en face imaging with focus tracking must be employed. We present a method for increasing the apparent transverse resolution in OCT outside of the confocal parameter using Gaussian beam deconvolution of adjacent axial scans, and thereby reducing the limitations associated with the hourglass profile of a tightly focused Gaussian beam. Specifically, our method determines how measurements depend on the object when blurred with a Gaussian beam, and subsequently finds an estimate of the original object. Possible reconstruction estimates are explored and evaluated using a variety of regularization techniques as well as estimation maximization algorithms. Numerical simulations demonstrate effectiveness of each technique. When applied to experimentally-acquired OCT data, the use of these algorithms can improve the apparent transverse resolution outside of the confocal parameter, extending the comparable confocal parameter range along the axial direction. These results are likely to further improve the high-resolution cross-sectional imaging capabilities of OCT.
منابع مشابه
Automatic estimation of point-spread-function for deconvoluting out-of-focus optical coherence tomographic images using information entropy-based approach
This paper proposes an automatic point spread function (PSF) estimation method to de-blur out-of-focus optical coherence tomography (OCT) images. The method utilizes Richardson-Lucy deconvolution algorithm to deconvolve noisy defocused images with a family of Gaussian PSFs with different beam spot sizes. Then, the best beam spot size is automatically estimated based on the discontinuity of info...
متن کاملClinical Applications of Optical Coherence Tomography in Ophthalmology
Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases. Furtherm...
متن کاملQuantifying the influence of Bessel beams on image quality in optical coherence tomography
Light scattered by turbid tissue is known to degrade optical coherence tomography (OCT) image contrast progressively with depth. Bessel beams have been proposed as an alternative to Gaussian beams to image deeper into turbid tissue. However, studies of turbid tissue comparing the image quality for different beam types are lacking. We present such a study, using numerically simulated beams and e...
متن کاملFeasibility Assessment of Optical Coherence Tomography-Guided Laser Labeling in Middle Cranial Fossa Approach
Introduction: Different approaches have been developed to find the position of the internal auditory canal (IAC)in middle cranial fossa approach. A feasibility study was performed to investigate the combination of cone beam computed tomography (CBCT), optical coherence tomography (OCT), and laser ablation to assist a surgeon in a middle cranial fossa approach by outlining the internal auditory ...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کامل