Background: Variety of implant design and quality are available and being used by orthopaedic surgeon to restore anatomy and enhance healing process of fractured bone. At times implants fail to achieve desired out come in few cases and a repeat surgery is required. This study evaluates causes of implant failure in fracture long bones. Methods: Retrospective study analyzing 53 patients with 66 long bone fractures with failed implants dividing them into plate, unlocked nails and locked nails group was performed at level – I trauma centre of tertiary level medical college in North India, during January 2011 to march 2014. After thorough clinico-radiological evaluation, results were analyzed. Results: Maximum implant failure occurred in 20-50 yrs of age. Lower limb long bone implant failure 48 (72.7%) was more common than upper limb long bones 18 (27.3%). In all three groups fatigue failure (39%) was most common followed by bending (27.2%), loosening (18.8%) and infection 15.5% was observed. Implants defer in design and quality from manufacturer to manufacturer. Surgeons had chosen implants according to their technical knowledge and surgical skills. Re-trauma and patient non-compliance with instructions was also important cause of implant failure. Conclusion: Cause of implant failure is multi-factorial hence we recommend use of suitable design and quality implant to match fracture configuration with proper surgical techniques. Patient should be educated and followed up according to rehabilitation protocol to avoid disappointments. Keywords; Implant failures, Fatigue failure, Long bone fractures, Implant corrosion, Implant loosening Access this article online Quick Response Code: Website: www.innovativepublication.com DOI: 10.5958/2395-1362.2016.00010.4 Introduction Fractures of long bones are common fractures encountered in Orthopaedic surgery. They are result of significant trauma and are often associated with considerable soft tissue damage. Trauma may vary from low to high to very high velocity changing the radiological and clinical picture in every case. Incidence of trauma related surgeries has increased in order to provide early rehabilitation and good quality of life. The implants are used to provide stability to fractured bone and maintain reduction and thus help in reducing fracture disease. Orthopaedic surgeons have been using variety of implants since past. Some implants have not shown good patient compatibility resulting in non union and infection in few cases. They are manufactured using different types of materials such as cobalt-chromium alloys, stainless steels, titanium and alloys that are in optimum combinations of biocompatibility, corrosion resistance, mechanical strength and cost effectiveness. 316 L austenitic type stainless steel is used in vast majority of implant but use of titanium and its alloys is on the rise. Implant failure is a complication associated with fracture management, screws and plates pull out, nails and plate loosen, bend and break and rods and pins migration. Implant failure increases patient’s morbidity, lengthens the healing process and increases the cost of treatment. An implant failure often leads to re-fracture, complicating the healing process and a more complicated repeat Surgery. In vast majority of these cases mechanics of fracture, implant design and surgical procedure are to be blamed. The aim of this study was to evaluate the cause of implant failure in fractures of long bones with intent to reduce the likely hood of reoccurrence. Material & Method The patients attending the orthopaedic OPD and level – I trauma centre at tertiary level medical college in North India, with fractures of long bones treated in past, where primary implant had failed to achieve the desired outcome and repeat surgery was required were included in study. The failure in achieving the desired outcome would be due to implant based factors; e.g. breakages, bending, corrosion/ metal reaction, patient based factors like early ambulation, excessive weight, poor hygiene care, non compliance to instructions or surgeon based factors or a combination of these or due to re-trauma. 53 patients with 66 long bones with implant failure were included and analyzed retrospectively for the evaluation of implant failure during Jan 2011 to March 2014. Sunil Kumar et al. Evaluation of Implant Failure in Long Bones Fractures – A Retrospective Study Indian Journal of Orthopaedics Surgery 2016;2(1):64-68 65 After selection patients were subjected to thorough history taking including mode of trauma, associated injury and illness, post operative activities including beginning of range of motion, ambulation and weight bearing on operated limb before bone healing. History of re-trauma and infection was also taken. All the necessary pre-operative, post operative data was collected and patient s were divided into 3 groups of plate, unlocked intra-medullary nail and locked intramedullary nail and then further necessary investigations were carried out to evaluate the cause behind the implant failure in these cases. Result & Observations Out of 53 patients there were 47 (80.3%) males and 6 (19.7%) female cases with age ranging from 7 yrs to more than 60 yrs. Maximum failure occurred in age group of 20 50 yrs. Out of total 66 long bones, implant failure was observed in 28 (42.7%) bones managed with plates, 22 (33.3%) bones managed with unlocked intra-medullary nails and 16 (24.2%) bones managed with locked intra-medullary nails. (Table 1) Implant failure was observed more commonly in lower limb 48 (72.7%) long bone fractures (femur & tibia) as compared to upper limb 18 (27.3%) long bones (humerus, radius, ulna). As per history and record analysis, out of 66 long bone fractures, 20 (30%) cases had open wounds at the time of initial injury 46 (69.7%) cases had close injury. Retrospective radiological analysis showed 40 (60.6%) long bones had unstable fracture configuration as compared to 26 (39.3%) having stable fracture pattern at the time of initial trauma. (Table 2) 57 (86%) long bone fractures were managed by open reduction techniques (28 with plates, 18 with unlocked nails & 11 with locked nails) as compared to only 09 (13%) long bones managed by closed reduction technique (4 with unlocked nail & 5 with locked nail) by surgeons at the time of initial surgery (Table 2). With in 28 plate failure group we found infection in 3, loosening in 5, bending in 7 and fatigue failure in 13 cases. Where as in 22 unlocked nail group bending of implant in 11, loosening in 4, fatigue failure in 4 cases and infection in 3 cases was observed. In 16 locked intra-medullary nail failure group, fatigue failure in 9 cases, loosening in 3 and infection in 3 cases were observed as the cause of implant failure (Table 3). Improper selection of implant and poor surgical techniques, skills were found to be more responsible for implant failure in study. Surgeons preferred open reduction techniques in most of the cases for fracture fixation. Improper selection of implant resulted in instability, non-union and subsequently fatigue failure, bending, loosening occurred with loading or re-trauma in few cases. Patient’s non compliance during rehabilitation and early ambulation was also found to responsible for implant failure. In our study fatigue failure 26 (39%) was more common among the failed implants, followed by bending 18 (27.2), loosening 12 (18.8%) and infection 10 (15.5%). Table 1: Numbers of failed implants and groups Number of failed implant in groups Group Frequency (n=66)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Prophylactic Effect of Methyl Prednisolone Sodium Succinate against Fat Embolism in Long Bones Fractures

In this prospective study the effect of low dose methylprednisolone succinate (10mg/kg) on the incidence of fat embolism syndrome and isolated arterial hypoxemia in 99 patients with long bone fracture (52 control and 47 steroid-trated subjects) was studied. Frequency of fractures among the selected patients was as follows: femoral fracture 52.5%, tibial fracture 36.4%, both femoral and tibial f...

متن کامل

Evaluation of the Etiologies of Implant Fracture in Patients With Fractures of the Implants of Lower Limbs’ Long Bones

BACKGROUND Orthopedics implants are important tools for treatment of bone fractures. Despite available recommendations for designing and making the implants, there are multiple cases of fracture of these implants in the body. Hence, in this study the frequency of failure of implants in long bones of lower extremities was evaluated. METHODS AND MATERIALS In this cross-sectional study, two type...

متن کامل

Risk Factors and Early Survival Rate of Biomet 3i Dental Implants. A Retrospective Study

Introdouction: Although highly desirable outcomes and longterm survival of dental implant treatments are well documented, implant failures still occur due to various reasons. Several risk factors may impair implant survival including implant dimensions (length, diameter, and implant design), procedures, local bone density at the implant site, and patient-related risk factors such as age, smokin...

متن کامل

The Evaluation of Mid face and Lower Face Fractures in Traumatic Patients Attended to Rasht Velayat Hospital: A Retrospective Study

Introdouction: The incidence and etiology of maxillofacial fractures are influenced by social, cultural, and environmental factors. Understanding the cause, severity, and temporal distribution of maxillofacial trauma provides an insight into the behavioral patterns of people from different countries and can also assist in establishing clinical and research priorities for effective treatment and...

متن کامل

Analysis of incidence and associated factors with fractured implants: a retrospective study.

Osseointegrated threaded titanium screw-type implants rarely lose integration after the first year of clinical function. Implant failure can occur for other reasons, with implant fracture being one of the major reasons for late failure. The purpose of the present study was to determine the incidence of implant fracture in completely edentulous and partially edentulous arches and to determine wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016