Evaluation of an indirect oscillometric blood pressure monitor in anaesthetised dogs at three different anatomical locations.

نویسندگان

  • M Fujiyama
  • H Sano
  • J P Chambers
  • M Gieseg
چکیده

AIMS To evaluate the agreement between invasive and non-invasive measurements of blood pressure (BP) using an oscillometer (PetTrust) at three different anatomical locations in anaesthetised dogs under different haemodynamic conditions. METHODS Eight adult Greyhounds weighing 23.5-36.5 kg were anaesthetised with isoflurane and positioned in dorsal recumbency. Systolic arterial pressure (SAP), diastolic arterial pressure (DAP) and mean arterial pressure (MAP) were measured invasively via a dorsal pedal artery and non-invasively using the oscillometer with cuffs placed above the carpus, above the tarsus and around the tail base. Phenylephrine was administered to induce vasoconstriction, dobutamine was used to increase cardiac output and increased end-tidal concentrations of isoflurane were used to induce vasodilation. Correlation between measurements was analysed by linear regression and agreement was analysed using Bland-Altman plots. RESULTS Seventy two representative measurements were obtained. Mean differences (bias) between invasive and non-invasive measurements were <5 mmHg except for DAP measured on the tail, and SD (precision) were <15 mm Hg except for SAP measured at the pelvic limb. Correlation coefficients were >0.9 except for SAP on the pelvic limb and DAP on the tail. More than 50 and 80% of values measured using oscillometry lay within 10 and 20 mmHg, respectively, of values measured invasively except for SAP on the tail. SAP tended to be overestimated when measured non-invasively at low BP, and be underestimated at high BP. DAP was underestimated during low BP and overestimated during high BP. Hypotension (MAP <60 mmHg) was detected by the oscillometer with a sensitivity ≥83% and specificity ≥98% at all locations. CONCLUSIONS This oscillometric device met the 2007 American College of Veterinary Internal Medicine guidelines for measurement of BP on the thoracic limb. There was good agreement between the oscillometer and invasive measurement of MAP at all locations. CLINICAL RELEVANCE MAP is the driving pressure for tissue perfusion, thus MAP measurement is clinically essential. This oscillometric device yields reliable MAP measurements at three anatomical locations over a wide range of BP and can identify hypotension with high sensitivity and specificity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of arterial blood pressure measurements and hypertension scores obtained by use of three indirect measurement devices in hospitalized dogs.

OBJECTIVE To evaluate the agreement of blood pressure measurements and hypertension scores obtained by use of 3 indirect arterial blood pressure measurement devices in hospitalized dogs. Design-Diagnostic test evaluation. ANIMALS 29 client-owned dogs. PROCEDURES 5 to 7 consecutive blood pressure readings were obtained from each dog on each of 3 occasions with a Doppler ultrasonic flow detec...

متن کامل

Comparison of Blood Pressure in Mature and Premature Neonates Using Direct and Indirect Methods of Measurement

The aim of this study was to evaluate the correspondence of blood pressure (BP) measured using the direct intra-arterial method and indirect oscillometric monitor method. Twenty-three newborns with radial arterial catheters inserted were enrolled in this study. The gestational age (GA) ranged from 25-40 weeks and birth weight (BW) ranged from 700-3,550 g. Direct BP was measured using radial art...

متن کامل

Accuracy of pulse interval timing in ambulatory blood pressure measurement

Blood pressure (BP) monitors rely on pulse detection. Some blood pressure monitors use pulse timings to analyse pulse interval variability for arrhythmia screening, but this assumes that the pulse interval timings detected from BP cuffs are accurate compared with RR intervals derived from ECG. In this study we compared the accuracy of pulse intervals detected using an ambulatory blood pressure ...

متن کامل

A clinical evaluation of blood pressure through non-invasive measurement using the oscillometric procedure in conscious dogs.

The oscillometric procedure was used to measure the heart rate as well as the systolic, mean, and diastolic blood pressures of 152 dogs (102 in the control group, 13 in the group with renal disease, 37 in the group with heart disease) who were brought to Azabu University of Veterinary Teaching Hospital. It was demonstrated that the blood pressure and heart rate of the control group lowered and ...

متن کامل

Quality Control and Validation of Oscillometric Blood Pressure Measurements Taken During an Epidemiological Investigation

This study aims to validate blood pressure (BP) values measured by an oscillometric BP monitor and seek possible calibration methods if discrepancies exist. Noninvasive BP measurement outcomes were determined using an oscillometric BP monitor (Omron HBP-1300) versus a mercury sphygmomanometer (standard device). Two percent of subjects enrolled in an epidemiological investigation were systematic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • New Zealand veterinary journal

دوره 65 4  شماره 

صفحات  -

تاریخ انتشار 2017