Artificial Neural Network for Parallel Transformers Tap-changer Control for Closed Primary Bus Connection

نویسندگان

  • Fakhrul Islam
  • Joarder Kamruzzaman
چکیده

Voltage control is an essential part of the electric energy transmission and distribution system to maintain proper voltage limit at the consumer’s terminal. Besides the generating units that provide the basic voltage control, there are many additional voltage-controlling agents e.g., shunt capacitors, shunt reactors, static VAr compensators, regulating transformers mentioned in [1], [2]. The most popular one, among all those agents for controlling voltage levels at the distribution and transmission system, is the on-load tap changer transformer. It serves two functions-energy transformation in different voltage levels and the voltage control. Artificial Neural Network (ANN) has been realized as a convenient tool that can be used in controlling the on load tap changer in the distribution transformers. Usage of the ANN in this area needs suitable training and testing data for performance analysis before the practical application. This paper briefly describes a procedure of processing the data to train an Artificial Neural Network (ANN) to control the tap changer operating decision of parallel transformers for a closed primary bus. The data set are used to train a two layer ANN using three different neural net learning algorithms, namely, Standard Backpropagation [3], Bayesian Regularization [4] and Scaled Conjugate Gradient [5]. The experimental results are presented including performance analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Neuro-Fuzzy Dynamic Programming to Improve the Reactive Power and Voltage Profile of a Distribution Substation

Improving the reactive power and voltage profile of a distribution substation is investigated in this paper. The purpose is to properly determination of the shunt capacitors on/off status and suitable tap changer (TC) position of a substation transformer. In addition, the limitation of secondary bus voltage, the maximum allowable number of switching operation in a day for on load tap changer an...

متن کامل

Tap-Changing Operations of Multiple Transformers using ANN Based Controller

Tap changing operations of multiple transformers at a substation is a complex problem due to issues in controlling the parallel operations of the transformers involved, differences in manufacturer’s design and inaccuracy of the measures. In earlier work Artificial Neural Network (ANN) based tap changer controller has been developed to overcome these difficulties and improved results have been s...

متن کامل

A Sensitive ANN Based Differential Relay for Transformer Protection with Security against CT Saturation and Tap Changer Operation

This paper presents an artificial neural network (ANN) based scheme for fault identification in power transformer protection. The proposed scheme is featured by the application of ANN to identifying system patterns, the unique choice of harmonics of positive sequence differential currents as ANN inputs, the effective handling of current transformer (CT) saturation with an ANN based approach, an...

متن کامل

Extending Operational Zone of Rotary Power Flow Controller by Controlling Tap-changers of Transformers

This paper proposes a method for extending the ability of rotary power flow controller (RPFC) using tap-changer of the RPFC’s transformers. A detailed model of the device is presented to analyze the effects of the tap changer operation on the performance of the RPFC. To evaluate the results, the RPFC model is simulated using PSCAD/EMTDC software. Dynamic operation of the RPFC on a 400 kV transm...

متن کامل

Fuzzy Logic Controller to Improve the Coordination of Cascaded Tap Changers

The transformers which connect the different voltage levels in transmission and distribution systems are supplied with on-load tap changing mechanism. The on-load tap changer maintains the voltage amplitude within the predefined limits at the so called regulation bus. In a radial feeder, the on-load tap changers are cascaded. Poor coordination between cascaded tap changers causes improper volta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003