Sensitivity of Quantitative Signal Detection in Regards to Pharmacological Neuroenhancement

نویسندگان

  • Maximilian Gahr
  • Bernhard J. Connemann
  • Carlos Schönfeldt-Lecuona
  • René Zeiss
چکیده

Pharmacological neuroenhancement (PNE) is a form of abuse and has not yet been addressed by methods of pharmacovigilance. In the present study, we tested if quantitative signal detection may be sensitive in regards to PNE. We evaluated the risk of drug abuse and dependence (DAAD) related to substances that are known to be used for PNE and divided this group into agents with (methylphenidate) and without a known abuse potential outside the field of PNE (atomoxetine, modafinil, acetylcholine esterase inhibitors, and memantine). Reporting odds ratios (RORs) were calculated using a case/non-case approach based on global and country-specific drug safety data from the Uppsala Monitoring Centre (UMC). Both control substances (diazepam and lorazepam) and methylphenidate were statistically associated with DAAD in all datasets (except methylphenidate in Italy). Modafinil was associated with DAAD in the total dataset (ROR, 2.7 (95% confidence interval (CI), 2.2-3.3)), Germany (ROR, 4.6 (95% CI, 1.8-11.5)), and the USA (ROR, 2.0 (95% CI, 1.6-2.5)). Atomoxetine was associated with DAAD in the total dataset (ROR, 1.3 (95% CI, 1.2-1.5)) and in the UK (ROR, 3.3 (95% CI, 1.8-6.1)). Apart from memantine, which was associated with DAAD in Germany (ROR, 1.8 (95% CI, 1.0-3.2)), no other antidementia drug was associated with DAAD. Quantitative signal detection is suitable to detect agents with a risk for DAAD. Its sensitivity regarding PNE is limited, although atomoxetine and modafinil, which do not have a known abuse potential outside PNE, and no antidementia drugs, whose use in PNE is presumably low, were associated with DAAD in our analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI

Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...

متن کامل

Using Signal Detection Theory to Investigate the Impact of Mood Induction on Emotional Information Processing in High BAS/BIS Individuals

Objective: The main objective of this study was to investigate the explicit memory bias in the people with high BAS/BIS sensitivity in the different manipulated mood states.  Methods: By using purposive sampling method, seventy-four participants (undergraduate students) were selected based on z-scores of 480 using the Carver and White’s BAS/BIS scale. They were distributed as: 24 wi...

متن کامل

How Realistic Are the Scientific Assumptions of the Neuroenhancement Debate? Assessing the Pharmacological Optimism and Neuroenhancement Prevalence Hypotheses

Since two decades, neuroenhancement is a major topic in neuroethics and still receives much attention in the scholarly literature as well as in public media. In contrast to high hopes at the beginning of the "Decade of the Brain" in the United States and Europe that we subsume under the "pharmacological optimism hypothesis," recent evidence from clinical neuroscience suggests that developing dr...

متن کامل

Synergetic signal amplification of multi-walled carbon nanotubes-Cetyltrimethylammonium Bromide and Poly-L-Arginine as a highly sensitive detection platform for Rutin

In this research, a glassy carbon electrode was coated with a thin layer of multi-walled carbon nanotubes in the presence of the surfactant and subsequently was electro-polymerized with Poly-L-arginine (P-L-Arg). The prepared electrode was used as an effective sensor for the quantitative detection of Rutin (Ru). The fabricated electrode exhibited good electrochemical performance with low electr...

متن کامل

Synergetic signal amplification of multi-walled carbon nanotubes-Cetyltrimethylammonium Bromide and Poly-L-Arginine as a highly sensitive detection platform for Rutin

In this research, a glassy carbon electrode was coated with a thin layer of multi-walled carbon nanotubes in the presence of the surfactant and subsequently was electro-polymerized with Poly-L-arginine (P-L-Arg). The prepared electrode was used as an effective sensor for the quantitative detection of Rutin (Ru). The fabricated electrode exhibited good electrochemical performance with low electr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017