Fractional encoding of harmonic motions in MR elastography.
نویسندگان
چکیده
In MR elastography (MRE) shear waves are magnetically encoded by bipolar gradients that usually oscillate with the same frequency fv as the mechanical vibration. As a result, both the repetition time (TR) and echo time (TE) of such an MRE sequence are greater than the vibration period 1/fv. This causes long acquisition times and considerable signal dephasing in tissue with short transverse relaxation times. Here we propose a reverse concept with TR<or=1/fv which we call "fractional" MRE, i.e., only a fraction of one vibration cycle per TR, can be used for motion sensitization. The benefit of fractional MRE is twofold: 1) acquisition times in seconds can be achieved for a single-phase difference wave image, and 2) materials that combine low elasticity, high viscosity, and short T2* relaxation times show an increased phase-to-noise ratio (PNR). A twofold increase of the phase signal is predicted for liver-like materials. Volunteer studies performed in liver and biceps show the benefit of fractional MRE. Furthermore, we demonstrate the feasibility of the technique for in vivo myocardial MRE by visualizing transverse wave propagation in the interventricular septum (IVS).
منابع مشابه
Application of DENSE-MR-elastography to the human heart.
Typically, MR-elastography (MRE) encodes the propagation of monochromatic acoustic waves in the MR-phase images via sinusoidal gradients characterized by a detection frequency equal to the frequency of the mechanical vibration. Therefore, the echo time of a conventional MRE sequence is typically longer than the vibration period which is critical for heart tissue exhibiting a short T(2). Thus, f...
متن کاملApplication of DENSE MR-Elastography to the human heart: first in vivo results
Introduction Typically, MR-Elastography (MRE) encodes the propagation of monochromatic acoustic waves in the MR-phase images via sinusoidal gradients characterized by a detection frequency equal to the frequency of the mechanical vibration [1]. Therefore, the echo time of a conventional MRE sequence is typically longer than the vibration period, which is critical for heart tissue exhibiting a s...
متن کاملIn vivo wideband multifrequency MR elastography of the human brain and liver.
PURPOSE To demonstrate the feasibility of in vivo wideband MR elastography (wMRE) using continuous, time-harmonic shear vibrations in the frequency range of 10-50 Hz. THEORY AND METHODS The method was tested in a gel phantom with marked mechanical loss. The brains and livers of eight volunteers were scanned by wMRE using multislice, single-shot MRE with optimized fractional encoding and synch...
متن کاملMagnetic resonance acoustic radiation force (impulse) imaging (MR-ARFI)
Background/introduction MR-ARFI adds to the rich toolbox of MR imaging methods for guiding focused ultrasound. MRI has exquisite soft tissue contrast for targeting focused ultrasound and a variety of contrast mechanisms for assessing the effect of focused ultrasound. In addition, MR can provide temperature mapping in near-realtime. MR-ARFI is an imaging method that compliments these other capab...
متن کاملAnalysis of Plane Waves in Anisotropic Magneto-Piezothermoelastic Diffusive Body with Fractional Order Derivative
In this paper the propagation of harmonic plane waves in a homogeneous anisotropic magneto-piezothermoelastic diffusive body with fractional order derivative is studied. The governing equations for a homogeneous transversely isotropic body in the context of the theory of thermoelasticity with diffusion given by Sherief et al. [1] are considered as a special case. It is found that three types of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 57 2 شماره
صفحات -
تاریخ انتشار 2007