A study on electric method for measuring root canal length.

نویسندگان

  • H Iizuka
  • K Hasegawa
  • M Takei
  • Y Kato
  • M Nihei
  • M Ohashi
چکیده

As a fundamental study on the electric method for measuring root canal length, the various factors which affect the measured impedance were investigated using a wide range of frequencies. 1) The impedance between two saliva ejectors in contact with the oral mucosa near the bilateral premolars in the lower arch generally showed low values. The difference between the maximum and minimum measured impedance was reduced and eventually approached zero as the frequency increased. 2) When a 1.0-mm length of the reamer tip was inserted into 2% agar containing 0.90% or 0.45% NaCl solution, the impedance in the former solution was lower than that in the latter. 3) When the impedance of a reamer covered with insulating tape except at the tip, and exposed in a glass tube containing 0.90% NaCl solution was compared, the former showed a higher value than the latter. The smaller the inner diameter of the glass tube into which the reamer was inserted, the higher was the impedance of the reamer. In every case, the measured impedance and the difference between them decreased as frequency increased. With regard to the electric method for measuring root canal length, the application of high frequency of more than 30 kHz was considered to keep the influence of such factors to a minimum and contribute to the improvement of this method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...

متن کامل

The fundamental operating principles of electronic root canal length measurement devices.

It is generally accepted that root canal treatment procedures should be confined within the root canal system. To achieve this objective the canal terminus must be detected accurately during canal preparation and precise control of working length during the process must be maintained. Several techniques have been used for determining the apical canal terminus including electronic methods. Howev...

متن کامل

In Vitro Comparative Study of the Working Length Determination with Radiovisiography and Conventional Radiography in Dilacerated Canals

Introduction: The aim of this study was to compare digital and conventional radiography in determining the working length of dilacerated canals.Methods: Thirty nine human extracted single-rooted teeth with root curvature more than 35 degrees were included in this study. After access preparation, a file was inserted into the canal and advanced until the file tip was visualized at the foramen. Wi...

متن کامل

An Invitro Evaluation of the Accuracy of Two Electronic Apex Locators to Determine Working Length in the Presence of Various Irrigants

BACKGROUND Cleaning and shaping of root canal system requires various irrigating solutions. The question is whether the presence of irrigation solution alters working length determination using apex locators. The purpose of this study was to compare the accuracy of Root ZX and i-Root apex locator for determining working length in the presence of different irrigating solution. MATERIALS AND ME...

متن کامل

Comparison of the maintenance of root canal anatomy in severely curved resin blocks using RaCe and Flexmaster rotary systems

Comparison of the maintenance of root canal anatomy in severely curved resin blocks using RaCe and Flexmaster rotary systems Dr. S. Khedmat* - Dr. M. Vahdatifar** *- Associate Professor of Endodontics Dept. - Faculty of Dentistry – Tehran University of Medical Sciences. **- Endodontist. Background and Aim: Various rotary systems are available on the market, therefore selection of a proper instr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Nihon University School of Dentistry

دوره 29 4  شماره 

صفحات  -

تاریخ انتشار 1987