The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups – finite element simulations and experimental tests

نویسندگان

  • Rami K Korhonen
  • Arto Koistinen
  • Yrjö T Konttinen
  • Seppo S Santavirta
  • Reijo Lappalainen
چکیده

BACKGROUND Contact pressure of UHMWPE acetabular cup has been shown to correlate with wear in total hip replacement (THR). The aim of the present study was to test the hypotheses that the cup geometry, abduction angle, thickness and clearance can modify the stresses in cemented polyethylene cups. METHODS Acetabular cups with different geometries (Link: IP and Lubinus eccentric) were tested cyclically in a simulator at 45 degrees and 60 degrees abduction angles. Finite element (FE) meshes were generated and two additional designs were reconstructed to test the effects of the cup clearance and thickness. Contact pressures at cup-head and cup-cement interfaces were calculated as a function of loading force at 45 degrees, 60 degrees and 80 degrees abduction angles. RESULTS At the cup-head interface, IP experienced lower contact pressures than the Lubinus eccentric at low loading forces. However, at higher loading forces, much higher contact pressures were produced on the surface of IP cup. An increase in the abduction angle increased contact pressure in the IP model, but this did not occur to any major extent with the Lubinus eccentric model. At the cup-cement interface, IP experienced lower contact pressures. Increased clearance between cup and head increased contact pressure both at cup-head and cup-cement interfaces, whereas a decreased thickness of polyethylene layer increased contact pressure only at the cup-cement interface. FE results were consistent with experimental tests and acetabular cup deformations. CONCLUSION FE analyses showed that geometrical design, thickness and abduction angle of the acetabular cup, as well as the clearance between the cup and head do change significantly the mechanical stresses experienced by a cemented UHMWPE acetabular cup. These factors should be taken into account in future development of THR prostheses. FE technique is a useful tool with which to address these issues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Comparative Analysis of a Novel Acetabular Component Against Hemispherical Component in Case of Extensive Acetabular Bone Defects A Study Of Finite Element Analysis

The purpose of this study was to evaluate the design of a cup using finite element method and to analyze possible effects of joint loading postoperatively, and its initial mechanical stability, so as to direct its further optimization. Finite‐element (FE) models of the cup with three wings and the hemispherical cup were created to calculate the stress pattern...

متن کامل

On the Displacement-Stress Continuous Finite Elements

For the analysis of composite media, three different compatible and mixed finite element formulations are presented which apriori enforce the continuity of stresses as well as displacements at the element interfaces. The formulations are applied for the analysis of hi-material interfaces in two problems often encountered in the field of orthopaedic biomechanics, that is the fixation analysis in...

متن کامل

Investigating the Effect of Joint Geometry of the Gas Tungsten Arc Welding Process on the Residual Stress and Distortion using the Finite Element Method

Although a few models have been proposed for 3D simulation of different welding processes, 2D models are still more effective in design goals, thus more popular due to the short-time analysis. In this research, replacing "time" by the "third dimension of place", the gas tungsten arc welding process was simulated by the finite element method in two dimensions and in a short time with acceptable ...

متن کامل

The Effect of Inclined U-Notch Geometry on Mode Ratio (KII/KI) under Mixed Mode (I + II) Loading

In inclined U-notches, the mixed mode (I + II) loading occurs and the mode ratio can be increased by varying the notch angle. In this paper, the effect of the inclined U-notch geometry, i.e. the notch depth, the notch angle, the notch root radius, and the position of the notch with respect to supports, on the mode ratio (KII/KI) have been studied. Three-point bending and plane strain condition ...

متن کامل

Design of Broaching Tool Using Finite Element Method for Achieving the Lowest Residual Tensile Stress in Machining of Ti6Al4V Alloy

The aim of this study, is to use finite element simulation to achieve the optimal geometry of a broaching tool that creates the lowest tensile stress at the machined surface of the Ti6Al4V alloy. It plays a major role in reducing production costs and improves the surface integrity of the machined parts. The type and amount of residual stress determined by the thermal and mechanical loads transm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioMedical Engineering OnLine

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2005