Input impedance of the pulmonary arterial system in normal man. Effects of respiration and comparison to systemic impedance.
نویسندگان
چکیده
Input impedance of the pulmonary arterial system was determined in 10 subjects undergoing elective cardiac catheterization. No cardiovascular or pulmonary disease was found in these patients. In five of the subjects, systemic arterial impedance was also obtained, so that both systems could be compared. Pulmonary and systemic peripheral resistances were 79 +/- 9 dynes sec/cm5 (mean +/- SEM) and 1016 +/- 50 dynes sec/cm5, respectively. Characteristic impedance of the pulmonary circulation was lower than the characteristic impedance of the systemic circulation: 20 +/- 1 dynes sec/cm5 vs. 47 +/- 9 dynes sec/cm5, respectively. Pulmonary pressure and flow spectra for both systems are also presented. The amplitudes of the harmonics of pressure and flow are smaller for the pulmonary circulation, which is consistent with the lower pressures and more rounded waveforms of the normal pulmonary circulation. In all 10 subjects, input impedance of the pulmonary system was examined during both the inspiratory and expiratory phases of respiration. There was no difference between inspiration and expiration in either pulmonary vascular resistance (77 +/- 10 dynes sec/cm5 vs. 80 +/- 9 dynes sec/cm5, respectively), characteristic impedance (20 +/- 1 dynes sec/cm5 vs. 20 +/- 1 dynes sec/cm5) or in the overall impedance spectrum. Quiet respiration, thus, has no effect on the pulmonary arterial load, and changes in pressure and flow must result from alterations in right ventricular performance.
منابع مشابه
An Official Journal of the American Heart Association Pulmonary Arterial Pulse Wave Velocity and Impedance in Man
Tlie differential pressure method of Womersley and McDonald was used to measure instantaneous blood flow in the main pulmonary artery in ten human subjects. Three subjects had normal pulmonary arterial pressures and flows, seven had mitral stenosis and pulmonary hypertension. The spectrum of input impedance versus frequency was similar to that previously reported for the dog and rabbit, with th...
متن کاملHY POXIA AND I TS INFLUEN CES ON THE CARDIOVASCULAR AND RESPIRATORY SYSTEMS OF SPONTANEOUSLY BREATHING CATS
Effects of acute systemic hypoxia on the cardiovascular system (CYS) and respiration of spontaneously breathing cats were studied in two conditions. 1): Hypoxic air (6-8% 02 in N2) was given to the animal to induce systemic hypoxia for 20 minutes. Hyperventilation at this condition lowered arterial C02 tension (PaC02 hypocapnia). 2): In the second run, induction of hypocapnia was prevented ...
متن کاملPulmonary arterial pulse wave velocity and impedance in man.
Tlie differential pressure method of Womersley and McDonald was used to measure instantaneous blood flow in the main pulmonary artery in ten human subjects. Three subjects had normal pulmonary arterial pressures and flows, seven had mitral stenosis and pulmonary hypertension. The spectrum of input impedance versus frequency was similar to that previously reported for the dog and rabbit, with th...
متن کاملModulation of pulmonary arterial input impedance during transition from inspiration to expiration.
We investigated whether respiration influences pulmonary arterial input impedance during transition from inspiration to expiration in five anesthetized, spontaneously breathing dogs. Impedance (Z) was separately assessed for heart beats occurring in inspiration, in expiration, and during the transition from inspiration to expiration (transitional beat). Transitional beats were scored by the rat...
متن کاملTHE EFFECTS OF CAPTOPRIL ON PULMONARY AND SYS TEMIC ARTERIAL PRESSURES IN HIGHALTITUDE PULMONARY HYPERTENSION
The purpose of this investigation was to assess the effect of captopril on both systemic (P.a) and pulmonary arterial pressures (PPA) in patients with high-altitude pulmonary hypertension (HAPH). Seventeen patients (mean age 44±6.8 years) with HAPH and mild to moderate systemic arterial hypertension were included in the study. All patients underwent right heart catheterization with measurem...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation research
دوره 54 6 شماره
صفحات -
تاریخ انتشار 1984