Regional differences in myocardial performance in the left ventricle of the dog.

نویسندگان

  • M M LeWinter
  • R S Kent
  • J M Kroener
  • T E Carew
  • J W Covell
چکیده

To determine whether significant regional differences in shortening exist in the canine left ventricle, the shortening characteristics of small segments of the circumferentially oriented hoop axis fibers and the more longitudinally oriented fibers near the epicardium were examined using pairs of ultrasound crystals placed at three levels of the left ventricular free wall in the open-chest dog. Mean control shortening of the hoop axis fibers near the apex of the left ventricle averaged 20% of the end-diastolic length, significantly greater than shortening at the midventricular (13%) or basal (14%) levels. During transient periods of aortic constriction, end-diastolic length increased significantly and the extent of shortening was maintained for the hoop axis fibers at the apical and midventricular levels; end-diastolic length did not change and shortening decreased at the basal level. The epicardial fibers shortened an average of 5.6% of their end-diastolic length during control conditions at all three sites and showed small, parallel changes in shortening and end-diastolic length during aortic constriction. We conclude that significantly greater hoop axis shortening occurs near the apex of the left ventricle and that at this level a uniformly contracting model is inappropriate. In addition, the response of the hoop axis fibers to increased aortic impedance is not homogeneous, with a significant reduction in shortening occurring only at the base of the left ventricle where end-diastolic length does not increase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Increase of uncoupling protein-2 expression in the ischemic rat heart

Introduction: Reactive oxygen species (ROS) have been suggested to play an important role in the myocardial damage induced by ischemia – reperfusion. One element believed to be activated by ROS and to contribute to the reduction of ROS production, is the uncoupling protein-2 (UCP2). The objective of this investigation was to explore the effect of myocardial ischemia reperfusion on cardiac UC...

متن کامل

Effect of losartan on NOX2 transcription following acute myocardial ischemia-reperfusion

Introduction: Nicotinamide adenine dinucleotide phosphate (NADPH) oxidase-2 (Nox2) is one of the predominant sources of ROS production during myocardial ischemia-reperfusion and can be induced by angiotensin II. The evidence suggests that pharmacological blockers of renin-angiotensin system can exert direct tissue effects independent of their ability to regulate blood pressure. The mechanism...

متن کامل

The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method

Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...

متن کامل

Detection of Cardiac Artery Disease by Using the DCAD (b) Module

Introduction: In patients with cardiac artery disease, a myocardial perfusion scan, which is a non-invasive method, is utilized. This study is conducted to develop an advantageous software applicable to quantitative myocardial SPECT perfusion. Material and Methods: Each cross-section of the left ventricle was segmented by applying a fuzzy clustering method. After obtaining the myocardial skelet...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 37 2  شماره 

صفحات  -

تاریخ انتشار 1975