Long-term Hemodialysis Corrects Left Ventricular Dyssynchrony in End-stage Renal Disease: A Study with Gated Technetium-99m Sestamibi Myocardial Perfusion Single-photon Emission Computed Tomography.
نویسندگان
چکیده
INTRODUCTION Left ventricular (LV) dyssynchrony is common in patients with end-stage renal disease (ESRD), and echocardiographic assessment has shown that it can be improved by a single session of hemodialysis (HD). The aim of this study was to assess the effects of chronic HD on LV dyssynchrony in patients ESRD by means of gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography (GSPECT) with phase analysis. MATERIALS AND METHODS Twelve patients with ESRD underwent GSPECT and echocardiography before the start of long-term HD (baseline) and 3 months later. In addition, 7 control subjects matched for age and sex underwent GSPECT and echocardiography within a 2-month period. To evaluate LV dyssynchrony, both histogram bandwidth (HBW) and phase standard deviation (PSD) were determined with phase analysis of GSPECT images. The end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction were also measured with GSPECT, and the LV mass index (LVMI) was measured with echocardiography. The LV dyssynchrony, volume, function, and mass were compared among control subjects, patients with ESRD at baseline, and patients with ESRD after 3 months of chronic HD. RESULTS The LV dyssynchrony, volume, and mass at baseline were significantly greater in patients with ESRD than in control subjects (HBW, 65.5°±54.4° vs. 22.3°±7.5°, P<0.05; PSD, 21.0°±15.5° vs. 7.6°±5.5°, P<0.05; EDV, 105.7±29.2 vs. 72.3±13.9 mL, P<0.05; ESV, 44.3±22.1 vs. 20.9±10.3 mL, P<0.05; LVMI, 136.5±48.3 vs. 65.4±5.6 g/m(2), P<0.01). From baseline to the third month of chronic HD, there were significant increases in EDV (78.6±25.4 vs. 105.7±29.2 mL, P<0.01) and ESV (27.6±16.2 vs. 44.3±22.1 mL, P<0.01) and significant decreases in HBW (65.5°±54.4° vs. 31.0°±15.7°, P<0.01) and PSD (21.0°±15.5° vs. 10.0°±8.2°, P<0.01). CONCLUSION Chronic HD decreased LV dyssynchrony and volume in patients with ESRD. Serial phase analysis of GSPECT images is a useful method of assessing the effects of long-term HD on LV dyssynchrony and volume in patients with ESRD.
منابع مشابه
Left Ventricular Dyssynchrony in Patients with Moderate Coronary Stenosis and Border Line Fractional Flow Reserve
The cutoff values of fractional flow reserve (FFR) to detect physiological myocardial ischemia are still controversial. Some studies have reported that left ventricular (LV) dyssynchrony occurs in patients with coronary artery disease (CAD). The purpose of this study was to investigate LV dyssynchrony in patients with moderate coronary stenosis and borderline FFR, using stress electrocardiograp...
متن کاملPrediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography
Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...
متن کاملEvaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy
Introduction: The aim of this study was to evaluate the effect of successful kidney transplantation (KT) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-SPECT) in patients suffering from end-stage renal disease. ...
متن کاملClinical usefulness of Tc-99m hexakis 2-methoxyisobutyl isonitrile gated spect in patients with dilated cardiomyopathy: retrospective analysis.
BACKGROUND In Dilated cardiomyopathy the heart is enlarged and ventricles are dilated. Gated myocardial perfusion single photon emission computed tomography is considered state of the art for myocardial perfusion imaging. A retrospective analysis was conducted to evaluate patients with dilated cardiomyopathy with Tc-99m sestamibi gated myocardial perfusion single photon emission computed tomogr...
متن کاملNormal limits for left ventricular ejection fraction and volumes determined by gated single photon emission computed tomography – a comparison between two quantification methods
To compare gender-related normal limits for left ventricular (LV) ejection fraction (EF), end-diastolic and end-systolic volumes (EDV and ESV), obtained using two myocardial perfusion-gated single photon emission computed tomography (SPECT) quantification methods. A total of 185 patients were retrospectively selected from a consecutive series of patients examined for coronary artery disease (CA...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of Nippon Medical School = Nippon Ika Daigaku zasshi
دوره 82 2 شماره
صفحات -
تاریخ انتشار 2015