Lacrimal scintigraphy. II. Its role in the diagnosis of epiphora.

نویسندگان

  • L A Amanat
  • T E Hilditch
  • C S Kwok
چکیده

Lacrimal scintigraphy (LS) was performed in 860 lacrimal drainage systems (LDS) in 188 patients with bilateral epiphora and 226 patients with unilateral epiphora. A very high incidence of canalicular obstruction was found in these patients, the incidence being higher in the group with unilateral epiphora. It is suggested that a canalicular block is a commoner cause of obstructive epiphora than has been recognised previously and that LS is a reliable method of studying the canalicular function. A significant number (42%) of the opposite asymptomatic eyes of patients with unilateral epiphora were found to have an abnormality in the LDS, which supports the view that abnormalities in the LDS tend to be bilateral. Only 25% of these asymptomatic systems showed a normal drainage, confirming that physiological obstruction can exist below the lacrimal sac in normal lacrimal drainage systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of lacrimal drainage system by radionuclide dacryoscintigraphy in patients with epiphora

Introduction: This study was done to determine the site of obstruction in lacrimal drainage system in Asian patients suffering from epiphora and to determine the transit time taken for the tracer material to reach the lacrimal sac and the nasal cavity. Methods:Dacryoscintigraphy was performed using radionuclide technetium-99m pertechnetate (99m...

متن کامل

Role of lacrimal scintigraphy and subtraction macrodacryocystography in the management of epiphora.

Fifty-one patients were investigated by subtraction macrodacryocystography (SMDCG, 103 systems) and by lacrimal scintigraphy (LS, 105 systems). It was found that these investigations complemented each other and between them the precise site of obstruction in the lacrimal drainage apparatus could be determined in 80%. The radiation dosage to the lens in SMDCG significant, and it is therefore rec...

متن کامل

External Dacryocystorhinostomy for the Treatment of Functional Nasolacrimal Drainage Obstruction

OBJECTIVES To determine the outcome and long-term efficacy of external dacryocystorhinostomy (ext-DCR) with or without bicanalicular silicon intubation in patients with functional nasolacrimal drainage obstruction (FNLDO). MATERIALS AND METHODS Patients with epiphora and patent lacrimal systems on nasolacrimal irrigation were prospectively enrolled in the study. Each patient was assessed with...

متن کامل

Clinical and scintigraphic comparison of silicone and polyvinylpyrrolidone coated silicone perforated plugs.

BACKGROUND/AIM Isolated stenosis of the lacrimal punctum is a frequent cause of epiphora. Treatment relies on surgical opening or dilatation with bi- or monocanalicular prosthesis. Recently, silicone perforated punctum plugs (PPP) were proposed. The drawback with these silicone PPP was that secretions accumulate in the central orifice blocking the spontaneous flow of tears. A modification of th...

متن کامل

Comparison of dacryocystography and lacrimal scintigraphy in the diagnosis of functional nasolacrimal duct obstruction.

AIM It appears from the literature that no standardised examination exists for patients with functional nasolacrimal duct obstruction. The role of dacryocystography and lacrimal scintigraphy was compared in the diagnosis and management of these patients. METHOD Patients who were clinically diagnosed as having unilateral or bilateral functional nasolacrimal duct obstruction were prospectively ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 67 11  شماره 

صفحات  -

تاریخ انتشار 1983