Influence of the sample anticoagulant on the measurements of impedance aggregometry in cardiac surgery

نویسندگان

  • Cristina Solomon
  • Michael Winterhalter
  • Isabel Gilde
  • Ludwig Hoy
  • Andreas Calatzis
  • Niels Rahe-Meyer
چکیده

BACKGROUND The standard method of assessment of platelet function is represented by light transmission aggregometry (LTA), performed in citrated platelet-rich plasma (PRP). With LTA, decrease and subsequent post-cardiopulmonary bypass (CPB) recovery of platelet function have been reported during cardiac surgery. Multiple electrode aggregometry (MEA) may be used as point-of-care method to monitor perioperative changes in platelet function. Since MEA assesses macroaggregation which is influenced by the plasmatic levels of unbound calcium, citrate may be inadequate as anticoagulant for MEA. We used citrate and heparin for MEA samples, to see with which anticoagulant the intraoperative decrease and postoperative recovery in platelet function previously described with other aggregometric methods in cardiac surgery may be observed with MEA. METHODS Blood was obtained from 60 patients undergoing routine cardiac surgery and the samples were collected in standard tubes containing unfractionated heparin (50 U/mL) or trisodium citrate (3.2%). The samples were obtained before CPB, at 30 minutes on CPB, end of CPB and on the first postoperative day. MEA was performed using the Multiplate® analyzer. Collagen (COLtest, 100 μg/mL) and TRAP-6 (thrombin receptor activating peptide, TRAPtest, 1mM/mL) were used as aggregation agonists. RESULTS Platelet aggregometric response decreased significantly during CPB. Platelet aggregation assessed using TRAP-6 as agonist on heparinized blood significantly correlated with the duration of CPB (r = -0.41, p = 0.001, 2-tailed Pearson test). The aggregometric analysis performed on the first postoperative day showed a significant recovery in platelet activity in the samples containing heparin (increase from 30 ± 22 U to 46 ± 27 U for the COLtest and from 70 ± 34 U to 95 ± 32 U for the TRAPtest, p < 0.001, Student's t-test), while no significant recovery of platelet function could be established in the MEA measurements performed with citrated blood. CONCLUSIONS The choice of blood sample anticoagulant used for impedance aggregometry influenced the platelet aggregation response. Postoperative platelet function recovery was only detected in the heparinized samples. Heparin seems to be better suited than citrate for the analysis of impedance aggregometry in heart surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring of coagulation and platelet function

Background: Paediatric cardiac surgery has developed dramatically during the last decades. Today, a wide range of patients is operated on-from premature neonates to grown up children with congenital heart disease. Excessive bleeding during and after cardiac surgery is still common, and it is one of the most serious complications. In this thesis, we consider different aspects of monitoring of co...

متن کامل

Platelet Aggregometry Interpretation Using Rotem – Part – Ii

The ROTEM platelet system is a new module that can be added to the ROTEM, enabling simultaneous analysis of thromboelastometry measurements and platelet aggregation using impedance aggregometry.

متن کامل

Cardiac Metastasis of Breast Cancer: A Case Report

Breast cancer is one of the most common cancers in women. As we know, cardiac metastases occur rarely. In this study, a 40-year-old woman referred to the hospital due to severe pain in the right leg. She was diagnosed with deep vein thrombosis (DVT) and received treatment, but, after one month and a half she returned with severe pain, exacerbated shortness of breath, cramping pain, and chest pa...

متن کامل

Anticoagulant action of low, physiologic, and high albumin levels in whole blood

Albumin is the most abundant plasma protein. Critical illness is often associated with altered, predominately decreased, serum albumin levels. This hypoalbuminaemia is usually corrected by administration of exogenous albumin. This study aimed to track the concentration-dependent influence of albumin on blood coagulation in vitro. Whole blood (WB) samples from 25 volunteers were prepared to cont...

متن کامل

Study the Effect of Silicon Nanowire Length on Characteristics of Silicon Nanowire Based Solar Cells by Using Impedance Spectroscopy

Silicon nanowire (SiNW) arrays were produced by electroless method on polycrystalline Si substrate, in HF/ AgNO3 solution. Although the monocrystalline silicon wafer is commonly utilized as a perfect substrate, polycrystalline silicon as a low cost substrate was used in this work for photovoltaic applications. In order to study the influence of etching time (which affects the SiNWs length) on d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2008