Joint myocardial T1 and T2 mapping using a combination of saturation recovery and T2 -preparation.
نویسندگان
چکیده
PURPOSE To develop a heart-rate independent breath-held joint T1 -T2 mapping sequence for accurate simultaneous estimation of coregistered myocardial T1 and T2 maps. METHODS A novel preparation scheme combining both a saturation pulse and T2 -preparation in a single R-R interval is introduced. The time between these two pulses, as well as the duration of the T2 -preparation is varied in each heartbeat, acquiring images with different T1 and T2 weightings, and no magnetization dependence on previous images. Inherently coregistered T1 and T2 maps are calculated from these images. Phantom imaging is performed to compare the proposed maps with spin echo references. In vivo imaging is performed in ten subjects, comparing the accuracy and precision of the proposed technique to existing myocardial T1 and T2 mapping sequences of the same duration. RESULTS Phantom experiments show that the proposed technique provides accurate quantification of T1 and T2 values over a wide-range (T1 : 260 ms to 1460 ms, T2 : 40 ms to 200 ms). In vivo imaging shows that the proposed sequence quantifies T1 and T2 values similar to a saturation-based T1 mapping and a conventional breath-hold T2 mapping sequence, respectively. CONCLUSION The proposed sequence allows joint estimation of accurate and coregistered quantitative myocardial T1 and T2 maps in a single breath-hold. Magn Reson Med 76:888-896, 2016. © 2015 Wiley Periodicals, Inc.
منابع مشابه
Joint myocardial T1 and T2 mapping
Background Recent studies suggest that quantitative myocardial T1 mapping allows assessment of focal and diffuse fibrosis in the myocardium [1]. Quantitative T2 mapping has also been proposed to overcome challenges associated with T2 weighted imaging [2]. These maps are traditionally acquired with different sequences, necessitating image registration to evaluate them jointly. A sequence that ca...
متن کاملSaturation recovery single-shot acquisition (SASHA) for myocardial T(1) mapping.
PURPOSE To validate a new saturation recovery single-shot acquisition (SASHA) pulse sequence for T1 mapping and to compare SASHA T1 values in heart failure patients and healthy controls. THEORY The SASHA sequence consists of 10 electrocardiogram-triggered single-shot balanced steady-state free precession images in a breath-hold. The first image is acquired without magnetization preparation an...
متن کاملValidation of a T1 and T2 mapping software for quantitative MRI
Methods The T1 & T2 mapping modules were implemented in Segment [3] and support the pulse sequence types shown in Table 1. T1 estimates were initialized by a lookup table search in an interval of 0-4000 ms and a 5 ms gap between entries. T2 estimates were initialized by linear regression to the signal logarithm. Relaxation time estimates were refined using a C-implementation of the Nelder-Mead ...
متن کاملT2-dependent errors in MOLLI T1 values: simulations, phantoms, and in-vivo studies
Background Diffuse myocardial fibrosis occurs in various cardiomyopathies and can be indirectly assessed with blood and myocardial T1 mapping at baseline and after gadolinium administration. The widely used MOdified Look-Locker Inversion-recovery (MOLLI) [1] sequence is known to underestimate myocardial T1 at higher heart rates, but its dependence on T2 has not been explored. We investigate MOL...
متن کاملMyocardial T1 and T2 mapping at 3 T: reference values, influencing factors and implications
BACKGROUND Myocardial T1 and T2 mapping using cardiovascular magnetic resonance (CMR) are promising to improve tissue characterization and early disease detection. This study aimed at analyzing the feasibility of T1 and T2 mapping at 3 T and providing reference values. METHODS Sixty healthy volunteers (30 males/females, each 20 from 20-39 years, 40-59 years, 60-80 years) underwent left-ventri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 76 3 شماره
صفحات -
تاریخ انتشار 2016