Harmonization Study Between LC‐MS/MS and Diasorin RIA for Measurement of 25‐Hydroxyvitamin D Concentrations in a Large Population Survey

نویسندگان

  • Diane J. Berry
  • John Dutton
  • William D. Fraser
  • Marjo‐Riitta Järvelin
  • Elina Hyppönen
چکیده

BACKGROUND Population-based research on vitamin D has increased dramatically in recent years. Such studies are typically reliant on assay procedures to measure reliable and comparable levels of 25-hydroxyvitamin D [25(OH)D] concentrations. METHODS Concentrations of 25(OH)D3 and 25(OH)D2 were measured using LC-MS/MS in 5,915 participants (aged 31 years) of Northern Finland Birth Cohort 1966. Blood samples were assayed in batches over a course of 18 months. As anomalies were present in the measurements, 200 samples were reassayed using Diasorin RIA. Agreement between measurements was assessed by Passing-Bablok regression and limits of agreement (LoA). To harmonize LC-MS/MS with Diasorin RIA measurements, formulae were derived from the LoA. RESULTS Concentrations measured by LC-MS/MS were much higher than those measured by Diasorin RIA, with a mean difference of 12.9 ng/ml. Constant variation was evident between batch measurements after log transformation. Statistical formula was applied separately for each batch of LC-MS/MS measurements, enabling us to remove both the constant and proportional bias that was evident prior to the transformation. CONCLUSION Despite the introduction of schemes/programs to improve accuracy of assays to measure 25(OH)D, significant differences can still happen. In these instances, methods to harmonize measurements based on a relatively small number of replicates can be successfully applied to establish confidence and to enable between-study comparisons.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HPLC method for 25-hydroxyvitamin D measurement: comparison with contemporary assays.

BACKGROUND The concentration of 25-hydroxyvitamin D [25(OH)D] in serum has been designated the functional indicator of vitamin D (VitD) nutritional status. Unfortunately, variability among 25(OH)D assays limits clinician ability to monitor VitD status, supplementation, and toxicity. METHODS We developed an HPLC method that selectively measures 25-hydroxyvitamin D2 [25(OH)D2] and D3 [25(OH)D3]...

متن کامل

Efficacy of the Measurement of 25-Hydroxyvitamin D2 and D3 Levels by Using PerkinElmer Liquid Chromatography-Tandem Mass Spectrometry Vitamin D Kit Compared With DiaSorin Radioimmunoassay Kit and Elecsys Vitamin D Total Assay

Vitamin D2 (ergocalciferol) and D3 (cholecalciferol) can be procured from exogenous sources. These are then metabolized to 25-hydroxyvitamin D (25OHD2 and 25OHD3) in the liver. Measuring the levels of both 25OHD2 and 25OHD3 is imperative in assessing clinical nutritional status [1]. Vitamin D2 or D3 is provided as a vitamin D supplement in many countries. Serum 25OHD levels can be measured by c...

متن کامل

Standardization of Misleading Immunoassay Based 25-Hydroxyvitamin D Levels with Liquid Chromatography Tandem-Mass Spectrometry in a Large Cohort Study

BACKGROUND The interest in vitamin D measurement has strongly increased in recent years. The best indicator for circulating vitamin D levels is 25-hydroxy-vitamin D (25(OH)D) which is often measured by different immunoassays. We demonstrate problems in comparability of measures by different immunoassays and the need for standardization in the context of a large population-based cohort study. ...

متن کامل

Multicenter comparison study of current methods to measure 25-hydroxyvitamin D in serum.

OBJECTIVES Measurement of serum 25-hydroxyvitamin D [25(OH)D] is generally considered to be a reliable indicator of vitamin D status. The recent increase in diversity of 25(OH)D assays prompted us to evaluate the performance of chromatographic methods (two in-house ID-LC-MS/MS and HPLC (ClinRep, Recipe)), a protein binding method (Cobas-25(OH)D-total, Roche) and immunochemical methods (Liaison ...

متن کامل

25-Hydroxyvitamin D assays: the quest for accuracy.

The recently reported difficulties experienced by Quest Laboratories (1 ) have once again highlighted concerns about the reliability of 25-hydroxyvitamin D (25-OHD) results, particularly those generated by liquid chromatography–tandem mass spectrometry (LC-MS/ MS), the method used by Quest. In the New York Times article of January 8, 2009 (1 ), a spokesman for Quest admitted that some erroneous...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 31  شماره 

صفحات  -

تاریخ انتشار 2017