New grading system based on magnetic resonance imaging in a mouse model of subarachnoid hemorrhage.
نویسندگان
چکیده
BACKGROUND AND PURPOSE A grading system for experimental subarachnoid hemorrhage (SAH) that does not require animal euthanasia is currently unavailable. We proposed a new grading system based on MRI and evaluated the feasibility of this method in a mouse model of SAH. METHODS SAH was induced by endovascular perforation in adult male C57BL/6 mice. Mice underwent MRI 24 hours after SAH and were categorized into the following 5 grades based on T2*-weighted imaging: Grade 0, no visible SAH or intraventricular hemorrhage (IVH); Grade 1, minimal/localized SAH without IVH; Grade 2, minimal/localized SAH with IVH; Grade 3, thick/diffuse SAH without IVH; and Grade 4, thick/diffuse SAH with IVH. Neurological deficits were then assessed and the mice euthanized for conventional SAH grading. RESULTS Among a total of 47 mice, 4% were scored as grade 0, 30% as grade 1, 11% as grade 2, 30% as grade 3, and 26% as grade 4. This MRI grading had excellent interobserver reliability (weighted κ value =0.94), and there were strong correlations between the MRI grading and the conventional grading (r=0.85; P<0.001) or between MRI grade and neurological scores (r=-0.46; P<0.01). CONCLUSIONS The new MRI grading correlated well with conventional grading and enabled in vivo evaluation of SAH severity. This grading system may offer advantages in future studies of experimental SAH.
منابع مشابه
Value of Three-Dimensional Maximum Intensity Projection Display to Assist in Magnetic Resonance Imaging (MRI)-Based Grading in a Mouse Model of Subarachnoid Hemorrhage
BACKGROUND Subarachnoid hemorrhage (SAH) is one of the most devastating cerebrovascular disorders. We report on the diagnostic value of three-dimensional (3-D) maximum intensity projection (MIP) reconstruction of T2*-weighted magnetic resonance images (MRI), processed using graphical user interface-based software, to aid in the accurate grading of endovascular-perforation-induced SAH in a mouse...
متن کاملSuccessful serial imaging of the mouse cerebral arteries using conventional 3-T magnetic resonance imaging.
Serial imaging studies can be useful in characterizing the pathologic and physiologic remodeling of cerebral arteries in various mouse models. We tested the feasibility of using a readily available, conventional 3-T magnetic resonance imaging (MRI) to serially image cerebrovascular remodeling in mice. We utilized a mouse model of intracranial aneurysm as a mouse model of the dynamic, pathologic...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملFabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...
متن کاملA New Theranostic System Based on Gd2O3 NPs coated Polycyclodextrin Functionalized Glucose for Molecular Magnetic Resonance Imaging (MMRI).
Introduction: Recent advances in nanoscience and biomedicine have attracted tremendous attention over the past decade to design and construct multifunctional nanoparticles that combine targeting, therapeutic, and diagnostic functions with a single platform to overcome the problems of conventional techniques for diagnosis and therapy with minimal toxicity. Materials ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 46 2 شماره
صفحات -
تاریخ انتشار 2015