Reduction in distal emboli with proximal flow control during mechanical thrombectomy: a quantitative in vitro study.
نویسندگان
چکیده
BACKGROUND AND PURPOSE To evaluate the impact of proximal flow control on efficacy and safety of mechanical thrombectomy in an in vitro middle cerebral artery occlusion. METHODS Three independent variables, including clot type, device (Merci Retriever, Solitaire FR, and Trevo devices), and use of a balloon guide catheter, were used to ascertain the impact of proximal flow control on the size and number of distal emboli generated during thrombectomy. Secondary end points were the recanalization rate and amount of flow restored. RESULTS Use of the balloon guide catheter during thrombectomy of the fragile, hard clot significantly reduced the formation of large distal emboli with a diameter >1 mm, regardless of the device used (P<0.01). Applying aspiration via the balloon guide catheter in place of the conventional guide catheter resulted in a significant increase of flow reversal (P<0.0001). Prior to thrombectomy, deployment of the stent-trievers produced immediate flow restoration through the soft and hard clot occlusions, 69.2 ± 27.3 and 45.5 ± 22.8 mL/min, respectively, that was preserved after the balloon inflation because of collateral flow via the posterior communication artery. After deployment but before thrombectomy, no flow was restored when using the Merci Retriever. After thrombectomy, complete flow restoration was achieved in a majority of cases. The Merci Retriever required more thrombectomy attempts to achieve hard clot removal compared with the stent-trievers when the conventional guide catheter was used (1.5 versus 1.1). CONCLUSIONS The risk of distal embolization was significantly reduced with the use of the balloon guide catheter.
منابع مشابه
Risk of distal embolization with stent retriever thrombectomy and ADAPT.
BACKGROUND There is a discrepancy in clinical outcomes and the achieved recanalization rates with stent retrievers in the endovascular treatment of ischemic stroke. It is our hypothesis that procedural release of embolic particulate may be one contributor to poor outcomes and is a modifiable risk. The goal of this study is to assess various treatment strategies that reduce the risk of distal em...
متن کاملMechanical thrombectomy for acute ischemic stroke: thrombus-device interaction, efficiency, and complications in vivo.
BACKGROUND AND PURPOSE Mechanical thrombectomy is a promising new modality of interventional stroke treatment. The various devices differ with regard to where they apply force on the thrombus, taking a proximal approach such as aspiration devices or a distal approach such as basket-like devices. The study compares the in vivo effectiveness and thrombus-device interaction of these 2 approaches. ...
متن کاملEfficacy of Balloon-Guiding Catheter for Mechanical Thrombectomy in Patients with Anterior Circulation Ischemic Stroke
OBJECTIVE To evaluate the efficacy of balloon guiding catheter (BGC) during thrombectomy in anterior circulation ischemic stroke. METHODS Sixty-two patients with acute anterior circulation ischemic stroke were treated with thrombectomy using a Solitaire stent from 2011 to 2016. Patients were divided into the BGC group (n=24, 39%) and the non-BGC group (n=38, 61%). The number of retrievals, pr...
متن کاملStatistical analysis of the association between rheological properties of blood and atherosclerosis
The aim of this study is to investigate the effects of non-Newtonian blood rheology models on the wall shear stress (WSS) distribution in a cohort of patients-specific coronary arteries. Twenty patients with diseased left anterior descending (LAD) coronary arteries (with varying degrees of stenosis severity from mild to severe) who underwent angiography and in-vivo pressure measurements were se...
متن کاملThe effect of flow arrest on distal embolic events during arterial occlusion with detachable coils: a canine study.
PURPOSE To determine the effect of proximal flow arrest on the frequency and timing of distal embolic events during occlusion of the common femoral artery with detachable coils. METHODS Twenty-three complex fibered platinum coils were delivered into 10 common femoral arteries without proximal flow arrest. The arteries were continuously monitored for flow and embolic events by Doppler sonograp...