PURPOSE To describe a methodology for establishing signal-to-noise ratios (SNRs) for different perimetric techniques, and to compare SNRs of frequency-doubling technology (FDT2) perimetry and standard automated perimetry (SAP). METHODS Fifteen patients with open-angle glaucoma (median MD, -2.6 dB, range +0.2 to -16.1 dB) were tested six times with FDT2 and SAP (SITA Standard program 24-2) within a 4-week period. Signals were estimated from the average superior-inferior difference between the mean deviation (MD) values in five mirror-pair sectors of the Glaucoma Hemifield Test, and noise from the dispersion of these differences over the six repeated tests. SNRs of FDT2 and SAP were compared by mixed-effects modeling. RESULTS There was moderate correlation between the signals of FDT2 and SAP (r(2) = 0.68, P < 0.001), but no correlation of noise (r(2) = 0.01, P = 0.16). Although both signal as well as noise estimates were higher with FDT2 compared with SAP, 60% to 70% of sector pairs showed higher SNRs with FDT2. The SNRs of FDT2 were between 20% and 40% higher than those of SAP (P = 0.01). There were no meaningful differences between parametric and nonparametric estimates of signal, noise, or SNR. CONCLUSION The higher SNRs of FDT2 suggest that this technique is at least as efficient as SAP at detecting localized visual field losses. Signal/noise analyses may provide a useful approach for comparing visual field tests independent of their decibel scales and may provide an initial indication of sensitivity to visual field change over time.
منابع مشابه
Assessment of the Wavelet Transform for Noise Reduction in Simulated PET Images
Introduction: An efficient method of tomographic imaging in nuclear medicine is positron emission tomography (PET). Compared to SPECT, PET has the advantages of higher levels of sensitivity, spatial resolution and more accurate quantification. However, high noise levels in the image limit its diagnostic utility. Noise removal in nuclear medicine is traditionally based on Fourier decomposition o...
متن کاملEffect of Exposure to a Mixture of Organic Solvents on Hearing Thresholds in Petrochemical Industry Workers
Introduction: Hearing loss is one of the most common occupational diseases. In most workplaces, workers are exposed to noise and solvents simultaneously, so the potential risk of hearing loss due to solvents may be attributed to noise. In this study we aimed to assess the effect of exposure to mixed aromatic solvents on hearing in the absence of exposure to hazardous noise. Materials and Met...
متن کاملInvestigation of the efficiency of various reactive mufflers by noise reduction and transmission loss analyses
Transmission loss and noise reduction of reactive mufflers are determined by linear acoustic theory and unsteady flow field study, respectively. The effects of extending the inlet tube of the muffler, adding holes to the extension, and the number of holes on both transmission loss and noise reduction are investigated. In noise reduction analysis, the Navier-Stokes equations and k-ε model are us...
متن کاملDevelopment and Validation of Sound Transmission Loss Measurement System for Measuring Muffler Performance
Muffler is a part of the vehicle exhaust system that absorb or reflect sound waves to reduce exhaust noise. One of the most important determinants of a muffler performance is the amount of attenuation that has on its input wave; this parameter is known as sound transmission loss. Four - mic standard test is one way to determine this parameter which is used in this paper. In this study, a test d...
متن کاملIntroduction to a simple yet effective Two-Dimensional Fuzzy Smoothing Filter
Annihilation or reduction of each kind of noise blended in correct data signals is a field that has attracted many researchers. It is a fact that fuzzy theory presents full capability in this field. Fuzzy filters are often strong in smoothing corrupted signals, whereas they have simple structures. In this paper, a new powerful yet simple fuzzy procedure is introduced for sharpness reduction in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 50 10 شماره
صفحات -
تاریخ انتشار 2009