Determination of Rhodium(III) Ions by Flame Atomic Absorption Spectrometry after Preconcentration with Modified Magnetic Activated Carbon

نویسندگان

  • M. Fayazi
  • R. Fayazi
چکیده

A new method for analysis of trace amount of Rh(III) ions by magnetic activated carbon modified with 2,3,5,6-tetra(2-pyridyl)pyrazine (MAC/TPPZ) as the magnetic sorbent has been proposed. The proposed adsorbent was found to be advantageous over conventional solid phase extraction (SPE) in terms ofoperational simplicity and low time-consuming. The experimental parametersaffecting the extraction/preconcentration and determination of the analyte were systematically examined. In order to investigate the selectivity of this magnetic sorbent, the effect of a variety of ions on preconcentration and recovery of Rh(III) ions were also investigated. Under optimum conditions, the calibration graph was linear for the concentration range of 0.8-650 μg l. The limit of detection (LOD, 3Sb/m) and the relative standard deviation (RSD, n = 8, c = 50 μg l) were 0.1 μg l and 3.6%, respectively. The maximum sorption capacity of the adsorbent for rhodium was found to be 21.6 mg g. The presented procedure was applied to monitoring rhodium in water and synthetic samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Rhodium(III) Ions by Flame Atomic Absorption Spectrometry after Preconcentration with Modified Magnetic Activated Carbon

A new method for analysis of trace amount of Rh(III) ions by magnetic activated carbon modified with 2,3,5,6-tetra(2-pyridyl)pyrazine (MAC/TPPZ) as the magnetic sorbent has been proposed. The proposed adsorbent was found to be advantageous over conventional solid phase extraction (SPE) in terms of operational simplicity and low time-consuming. The experimental parameters affecting the extractio...

متن کامل

Comparison of Modified Palladium Nanoparticles and Homemade Activated Carbon Derived from Medlar for Solid Phase Extraction of Metal Ions Prior to Their Flame Atomic Absorption Spectrometry Determination

This study focus on the preparation of two supports including activated carbon derived from medlar and Palladium nanoparticles loaded on activated carbon (Pd-NP-AC). Subsequently, both adsorbent modified with a novel Schiff base chelating agent and their potential applicability for determination of trace amounts of metal ions from aqueous solution has been investigated. The method is based on c...

متن کامل

The determination of Cu2+, Fe3+, Zn2+ and Pb2+ in real samples by flame atomic absorption spectrometry after their separation- preconcentration on 2-(2-nitrophenylazo)- naphthalen-1-ol loaded on activated carbon

A sensitive and simple method for simultaneous preconcentration of trace heavy metal ions in some cerealand vegetable samples has been reported. The method is based on the adsorption of Cu2+, Fe3+, Zn2+ and Pb2+on 2-(2-nitro-phenylazo)-naphthalen-1-ol (NPN) loaded on activated carbon (AC). The adsorbed metals onactivated carbon were eluted using 3 ml 4 mol L−1 nitric acid. The influences of the...

متن کامل

Chemically-Modified Activated Carbon with L-Arginine for Selective Solid Phase Extraction and Preconcentration of Metal Ions

In this study, a new sorbent of chemically-modified activated carbon with L-arginine (AC-Arg) has been produced as solid-phase extraction, to trace Zn(II) and Cd(II) ions in real samples, including soil and water samples, by Flame Atomic Absorption Spectrometry (FAAS). Once the surface coverage value is determined, the surface modification has been investigated and assessed, while having em...

متن کامل

Extraction and preconcentration of Pb(II) from water and soil samples using modified activated carbon

In this work, a new extractant was prepared by immobilizing ligand 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol, (5-Br-PADAP), on the activated carbon and applied to extraction of Pb(II) prior to determination by flame atomic absorption spectrometry. It was confirmed by FT- IR analysis. The metal ion was retained on the 0.05 g of the sorbent in the pH range 6-8, and then eluted with 5 mL of 0....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016