Sentinel Node Biopsy for the Head and Neck Using Contrast-Enhanced Ultrasonography Combined with Indocyanine Green Fluorescence in Animal Models: A Feasibility Study

نویسندگان

  • Yasunao Kogashiwa
  • Hiroyuki Sakurai
  • Yoshihiro Akimoto
  • Dai Sato
  • Tetsuya Ikeda
  • Yoshifumi Matsumoto
  • Yorihisa Moro
  • Toru Kimura
  • Yasuhiro Hamanoue
  • Takehiro Nakamura
  • Koichi Yamauchi
  • Koichiro Saito
  • Masashi Sugasawa
  • Naoyuki Kohno
  • Pei-Yi Chu
چکیده

BACKGROUND Sentinel node navigation surgery is gaining popularity in oral cancer. We assessed application of sentinel lymph node navigation surgery to pharyngeal and laryngeal cancers by evaluating the combination of contrast-enhanced ultrasonography and indocyanine green fluorescence in animal models. METHODS This was a prospective, nonrandomized, experimental study in rabbit and swine animal models. A mixture of indocyanine green and Sonazoid was used as the tracer. The tracer mixture was injected into the tongue, larynx, or pharynx. The sentinel lymph nodes were identified transcutaneously by infra-red camera and contrast-enhanced ultrasonography. Detection time and extraction time of the sentinel lymph nodes were measured. The safety of the tracer mixture in terms of mucosal reaction was evaluated macroscopically and microscopically. RESULTS Sentinel lymph nodes were detected transcutaneously by contrast-enhanced ultrasonography alone. The number of sentinel lymph nodes detected was one or two. Despite observation of contrast enhancement of Sonazoid for at least 90 minutes, the number of sentinel lymph nodes detected did not change. The average extraction time of sentinel lymph nodes was 4.8 minutes. Indocyanine green fluorescence offered visual information during lymph node biopsy. The safety of the tracer was confirmed by absence of laryngeal edema both macro and microscopically. CONCLUSIONS The combination method of indocyanine green fluorescence and contrast-enhanced ultrasonography for detecting sentinel lymph nodes during surgery for head and neck cancer seems promising, especially for pharyngeal and laryngeal cancer. Further clinical studies to confirm this are warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sentinel lymph node biopsy using real-time fluorescence navigation with indocyanine green in cutaneous head and neck/lip mucosa melanomas.

BACKGROUND The triple technique (lymphoscintigraphy, patent-blue staining, and a gamma probe) constitutes a reliable method for the sentinel lymph node (SLN) biopsy. However, in head and neck melanomas, a shine-through phenomenon, which occurs because these SLNs are close to the primary focus, is irreversibly problematic. To get around the shine-through phenomenon, this study uses the fluoresce...

متن کامل

In-House Handmade Camera for Indocyanine Green Video Angiography

Background and Aim: Vascular imaging during surgical procedures is very important and has many applications.  There are several methods for intraoperative vascular assessment such as intraoperative angiography, Doppler, and fluorescence-based techniques. The latter group and specially the Indocyanine Green (ICG) Video Angiography (VA) is commonly used for vascular surgery and sentinel node...

متن کامل

Indocyanine green fluorescence mapping of sentinel lymph node in patients with recurrent nasopharyngeal carcinoma after previous radiotherapy.

BACKGROUND The purpose of this study was to present the feasibility of indocyanine green (ICG) mapping of sentinel lymph node in recurrent nasopharyngeal carcinoma (NPC). M1ETHODS: Peritumoral injection of 5-mg ICG solution and real-time mapping of the sentinel lymph nodes in the neck was performed during surgery. The sentinel lymph node identified was excised and sent separately for laboratory...

متن کامل

Abstract 49. ICG Fluorescence with Lymphoscintigraphy for Sentinel Node Biopsy in Head and Neck Cutaneous Melanoma: A Reproducible, Reliable Means to Improve False Negative Rates

PURPOSE: Head and neck melanoma is associated with a high false negative sentinel lymph node biopsy (SLNB) rate. Our group previously demonstrated the combination of radiotracer and ICG SPY Elite navigation system was feasible and more sensitive compared to standard vital dye and radioactive tracer for SLNB. The goal of this report was to analyze our experiences utilizing ICG fluorescence with ...

متن کامل

Dual-modality imaging with 99mTc and fluorescent indocyanine green using surface-modified silica nanoparticles for biopsy of the sentinel lymph node: an animal study

BACKGROUND We propose a new approach to facilitate sentinel node biopsy examination by multimodality imaging in which radioactive and near-infrared (NIR) fluorescent nanoparticles depict deeply situated sentinel nodes and fluorescent nodes with anatomical resolution in the surgical field. For this purpose, we developed polyamidoamine (PAMAM)-coated silica nanoparticles loaded with technetium-99...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015