An evaluation of the NOVA I ion selective electrode analyser for sodium and potassium determination

نویسندگان

  • W. Annan
  • N. A. Kirwan
  • W. S. Robertson
  • P. R. Teasdale
  • B. P. Ager
چکیده

Introduction In the NOVA sodium and potassium analyser*, ion-selective electrodes measure sodium and potassium by direct potentiometry in separated plasma or serum or in the plasma phase of whole blood and in urine after dilution. Sodium is measured using a glass electrode and potassium using a valinomycin electrode. The sodium, potassium and reference electrodes all have a straight tube design and these are connected to a sampling probe, peristaltic pump and reagent pack via tubing and a pinch valve system. Samples can be aspirated from sample cups, capillary tubes or syringes. The sample volume required is 300 tl for blood, plasma or serum, or 100 ktl for urine. The NOVA is controlled by a microprocessor which initiates a two point calibration of the electrodes at 2 hourly intervals. A single point calibration with an aqueous standard is automatically carried out with the analysis of each specimen and the test result is displayed 58 seconds after the start of the sample aspiration cycle. The microprocessor also monitors the performance of the system and if a system fault is detected this is identified and a fault status code displayed. Urine diluent, standards, reference solution and a waste container, are all supplied in a disposable reagent pack within the instrument. The main operating controls consist of two push buttons labelled ’calibrate’ and ’analyze’, and auxiliary controls are also present. These comprise of a series of push buttons for other functions such as purging the system using a fast pump speed, testing the system display, displaying output from electrodes in millivolts and setting up the instrument for analysis in either ’blood’ or ’urine’ mode. The measurement of sodium and potassium in blood, serum or plasma is made on an undiluted sample, whereas urine samples are automatically diluted before analysis with magnesium acetate solution. After the recommended daily calibration of the instrument, a sample can be analysed with the push of a single control button and results are displayed in approximately one minute.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore

A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...

متن کامل

Evaluation of the Jokoo-ION 150 AC: Guidelines for the evaluation of analysers by ion-selective electrodes

The Jokoo-ION 150 AC is an automatic sodium, potassium and chloride analyser which uses ion-selective electrodes.The sample mode can be whole-blood, serum or urine. To evaluate a urine sample, a previous dilution (1:6) with the standard 1 solution is required. For three concentrations of control materials, the total precision (CV) ranged from 0.17 to 1.22% for sodium, 0.22 to 1.69% for potassiu...

متن کامل

Iodide selective membrane electrode based on copper (Π)-bis-Nphenilsalicyldenaminato complex

An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...

متن کامل

Construction of an Ion-Selective Eelectrode for Determination of permanganate Ion

A PVC ion-selective membrane electrode based on Cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of MnO4- ion. This electrode revealed good selectivity toward permanganate ion over a widevariety of anions. Effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...

متن کامل

Fabrication of an Electrochemical Sensor Based on a New Nano-ion Imprinted Polymer for Highly Selective and Sensitive Determination of Molybdate

In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 2  شماره 

صفحات  -

تاریخ انتشار 1980