First clinical study of a novel complete metal-free ceramic total knee replacement system

نویسندگان

  • E. Meier
  • K. Gelse
  • K. Trieb
  • M. Pachowsky
  • F. F. Hennig
  • A. Mauerer
چکیده

BACKGROUND The aim of the study was to evaluate the safety and efficacy of a novel metal-free ceramic total knee replacement system. METHODS Thirty-eight primary total knee arthroplasties (TKAs) were performed on 34 patients using the metal-free BPK-S ceramic total knee replacement system with both the femoral and tibial components of an alumina/zirconia ceramic composite. The clinical outcome was evaluated pre- and postoperatively at 3 (n = 32 TKA) and 12 months (n = 32 TKA) using the Knee Society Score (KSS), the Oxford Knee Score and the EQ-5D. Safety analysis was performed by radiological examination and assessment of adverse events. RESULTS Postoperatively, the KSS, Oxford Knee Score and EQ-5D improved significantly at 3 and 12 months (p < 0.001). Non-progressive partial radiolucent lines were observed in six cases, but there was no osteolysis and no implant loosening. Induction or exacerbation of allergies did not occur during the follow-up. CONCLUSIONS The metal-free BPK-S ceramic total knee replacement system proved to be a safe and clinically efficient alternative to metal implants in this short-term follow-up study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resection and Resolution of Bone Marrow Lesions Associated with an Improvement of Pain after Total Knee Replacement: A Novel Case Study Using a 3-Tesla Metal Artefact Reduction MRI Sequence

We present our case report using a novel metal artefact reduction magnetic resonance imaging (MRI) sequence to observe resolution of subchondral bone marrow lesions (BMLs), which are strongly associated with pain, in a patient after total knee replacement surgery. Large BMLs were seen preoperatively on the 3-Tesla MRI scans in a patient with severe end stage OA awaiting total knee replacement s...

متن کامل

Wear of Polyethylene against Metal-ceramic Composite Femoral Component: Effect of Aggressive Kinematic Conditions

INTRODUCTION Zirconium is a metal with excellent biocompatibility, which when oxidized is converted to the ceramic, zirconia. Composite-bearing materials have recently become available consisting of a metal zirconium core with an oxidized zirconia surface. The metal-ceramic composite has the wear characteristics of a ceramic bearing but with a much lower propensity for fracture. This dual advan...

متن کامل

The effect of Benson's relaxation technique on postoperative pain after total knee replacement in elder hospitalized patients in selected hospitals of kashan

Introduction: Pain is one of the most common problems in patients undergoing joint replacement. Except for medicinal treatments for pain relief, non-pharmacological methods of pain control, such as Benson's relaxation, cause more compromise with pain and reduce pain, fear and anxiety, and can tolerate it for the patient. The aim of this study was to determine the effect of Benson relaxation met...

متن کامل

Ceramic Femoral Components in Total Knee Arthroplasty - Two Year Follow-Up Results of an International Prospective Multi-Centre Study

BACKGROUND Total knee arthroplasty can be considered as a reliable surgical procedure with a good long-term clinical result. However, implant failure due to particle induced aseptic loosening as well as the aspect of hypersensitivity to metal ions still remains an emerging issue. METHODS The purpose of this prospective international multi-centre study was to evaluate the clinical and radiolog...

متن کامل

Total Knee Arthroplasty Failure Induced by Metal Hypersensitivity

BACKGROUND Metal hypersensitivity is an uncommon complication after total knee arthroplasty (TKA) that can lead to significant functional impairment and aseptic prosthesis failure. CASE REPORT We describe a 70-year-old patient who presented with persistent pain, swelling, and instability 2 years after a primary TKA. The patient had a history of metal hypersensitivity following bilateral metal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016