Removal of contrast media by different extracorporeal treatments.

نویسندگان

  • R Schindler
  • C Stahl
  • S Venz
  • K Ludat
  • W Krause
  • U Frei
چکیده

BACKGROUND Although the capability of extracorporeal treatments after administration of contrast media to prevent radiocontrast-induced nephropathy is controversial, haemodialysis is performed in many institutions after radiographic procedures. There are conflicting reports on the efficacy of different dialysers and treatment modalities to remove contrast media. METHODS We compared the contrast medium-removing ability of different extracorporeal treatments in a randomized trial. Thirty-nine patients on chronic renal-replacement therapy or with chronic renal failure were randomized to receive low-flux haemodialysis (Low-HD, n=10), high-flux haemodialysis (High-HD, n=10), online haemodiafiltration (HDF, 10 litre substitution, n=10) and online haemofiltration (HF, 18 litre substitution, n=9) after administration of contrast medium during routine radiological procedures. Plasma concentrations of contrast medium (iopromide or iomeprol) were measured by energy-dispersive X-ray fluorescence analysis. RESULTS The extraction ratio for contrast media was 0.64+/-0.1 for Low HD (P<0.05 vs. High-HD and vs. HDF), 0.74+/-0.1 for High-HD (P<0.05 vs. HF), 0.81+/-0.1 for HDF (P<0.05 vs HF), and 0.62+/-0.1 for HF. Mean extracorporeal plasma clearances were 82+/-2 for Low-HD (P<0.05 vs. High-HD and vs HDF), 100+/-2 for High-HD, 115+/-4 for HDF (P<0.05 vs. HF), and 86+/-5 ml/min for HF. CONCLUSIONS We conclude that HDF and High-HD remove contrast media more effectively than Low-HD and HF during the time of each treatment session. However, whether this is also true for the overall elimination of contrast media by these different procedures needs to be addressed in future studies, by a precise assessment of the drug time course after the session.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extracorporeal shock wave lithotripsy and intravenous contrast media application for localization of radiolucent calculi.

BACKGROUND AND PURPOSE The present study was carried out to compare the efficacy of ESWL treating radiolucent ureteric calculi visible in the ureter after application of contrast media. MATERIAL AND METHODS Medical records of 47 patients who had verified ureteric calculi by intravenous urography and retrograde pyelography were included in this study. Patients had undergone ESWL treatment afte...

متن کامل

Induction of DNA damage, apoptosis and micronuclei in peripheral blood lymphocytes following injection of contrast media in patients with abdominal CT scan

Background: Medical diagnostic procedures such as X-ray and computed Tomography (CT) scan account for considerable percent of patient's exposure to ionizing radiation. The exposure of cells to Ionization radiation results in induction of DNA damage and chromosomal aberrations. Contrast media (CM) are widely used in diagnostic radiology and CT scan. The aim of this study was to study adverse gen...

متن کامل

کاهش عوارض ناشی از مواد حاجب یددار تزریقی یونی و غیریونی

The risk of radiologic procedures is determined by different factors including contrast media, type of disease, procedure and skill of the physician. To reduce the contrast media-related risk, it is wise to use low osmolar contrast media (LOCM) in high-risk patients. When there is negligible cost difference between LOCM and other contrast media, it is wise to use LOCM for all patients. If an al...

متن کامل

Assessment of Contrast Media Volume Injected and Image Contrast in Abdominal Pelvic CT Scan and Related Factors in Referral Hospitals in Mazandaran, Iran

 Background and purpose: Computed tomography scan (CT) is highly capable of diagnosing abdominal and pelvic lesions. Injection of contrast media at appropriate concentration and volume provides the least side effects and the highest image quality. This study aimed at investigating the volume of contrast medium injected and the level of image contrast compared to the standard model, in the imagi...

متن کامل

Combined Effect of Iodine Contrast Media, Cisplatin and External Beam Radiotherapy on Anaplastic Thyroid Cancer Cells

Introduction: The current study investigated the combination of high Z atoms (iodine-, platinium-based drugs) with using low energy irradiation (120kvp) in Anaplastic Thyroid cancer cells.Materials and Methods: For this purpose, eight groups were designed: control (CNT), different concentrations of Iodine contrast media (ICM),  irradiation with various doses, Cis-platin (CDDP) with different c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 16 7  شماره 

صفحات  -

تاریخ انتشار 2001