Erg Assessment of Scotopic and Photopic Critical Flicker Frequency in Older and Younger Human Subjects

نویسندگان

  • Kristen Bowles
  • Timothy Kraft
  • KRISTEN BOWLES
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal Values of Standard Full Field Electroretinography in Healthy Subjects in Northern Iran

Background: Electroretinography (ERG) is known as a diagnostic test for evaluating the performance of different layers of the retina. Its normal values maybe different in different populations. Objectives: Determining the normal values of ERG parameters in patients presenting to an ophthalmologic center in Guilan in northern Iran. Materials and Methods: Fifty-five people presenting to a teach...

متن کامل

Asymmetrical Functional Deficits of ON and OFF Retinal Processing in the mdx3Cv Mouse Model of Duchenne Muscular Dystrophy.

Purpose The dystrophin mouse mutant mdx3Cv exhibits scotopic electroretinograpic (ERG) abnormalities, which resemble clinical changes observed in Duchenne muscular dystrophy (DMD) patients. In the present study, ERGs obtained from mdx3Cv and their wild-type littermates under scotopic, mesopic, and photopic conditions were analyzed to provide further insight on the affected retinal pathways, and...

متن کامل

Photopic 30 Hz flicker ERG as a predictor for rubeosis in central retinal vein occlusion.

AIMS To investigate the predictive value of the cone b-wave implicit time in the photopic compared with the scotopic 30 Hz flicker ERG for rubeosis in central retinal vein occlusion. METHODS 44 patients with a central retinal vein occlusion were examined with full field electroretinogram (ERG). RESULTS The average implicit time in the photopic 30 Hz flicker ERG in patients who developed rub...

متن کامل

Photopic and scotopic flicker sensitivity of a rod monochromat.

The sensitivity to sine-wave flicker of a rod monochromat was compared with that of a normal subject at photopic and scotopic levels of luminance. The sensitivity of the rod monochromat in the low-frequency region (below 3 Hz at scotopic levels and below 12 to 14 Hz at photopic levels) was found to be superior to that of the control. This superiority was most pronounced at photopic levels, wher...

متن کامل

Frequency-doubling illusion under scotopic illumination and in peripheral vision.

PURPOSE The authors sought to determine whether frequency-doubling illusion (FDI) could be perceived under scotopic illumination at central and peripheral retinal locations. For comparison, perception of the FDI at the central and peripheral retina under photopic illumination was also evaluated. METHODS Five subjects matched the apparent spatial frequency of counterphase flickering sinusoidal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009