Body composition determinants of radiation dose during abdominopelvic CT

نویسندگان

  • Patrick D. McLaughlin
  • Liam Chawke
  • Maria Twomey
  • Kevin P. Murphy
  • Siobhán B. O’Neill
  • Sebastian R. McWilliams
  • Karl James
  • Richard G. Kavanagh
  • Charles Sullivan
  • Faimee E. Chan
  • Niamh Moore
  • Owen J. O’Connor
  • Joseph A. Eustace
  • Michael M. Maher
چکیده

OBJECTIVES We designed a prospective study to investigate the in-vivo relationship between abdominal body composition and radiation exposure to determine the strongest body composition predictor of dose length product (DLP) at CT. METHODS Following institutional review board approval, quantitative analysis was performed prospectively on 239 consecutive patients who underwent abdominopelvic CT. DLP, BMI, volumes of abdominal adipose tissue, muscle, bone and solid organs were recorded. RESULTS All measured body composition parameters correlated positively with DLP. Linear regression (R2 = 0.77) revealed that total adipose volume was the strongest predictor of radiation exposure [B (95% CI) = 0.027(0.024-0.030), t=23.068, p < 0.001]. Stepwise linear regression using DLP as the dependent and BMI and total adipose tissue as independent variables demonstrated that total adipose tissue is more predictive of DLP than BMI [B (95% CI) = 16.045 (11.337-20.752), t=6.681, p < 0.001]. CONCLUSIONS The volume of adipose tissue was the strongest predictor of radiation exposure in our cohort. MAIN MESSAGE • Individual body composition variables correlate with DLP at abdominopelvic CT. • Total abdominal adipose tissue is the strongest predictor of radiation exposure. • Muscle volume is also a significant but weaker predictor of DLP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Survey of Pediatric CT Protocols and Radiation Doses in South Korean Hospitals to Optimize the Radiation Dose for Pediatric CT Scanning

Children are at greater risk of radiation exposure than adults because the rapidly dividing cells of children tend to be more radiosensitive and they have a longer expected life time in which to develop potential radiation injury. Some studies have surveyed computed tomography (CT) radiation doses and several studies have established diagnostic reference levels according to patient age or body ...

متن کامل

برآورد دوز جذبی ارگان‌های حساس به پرتو و دوز موثر بیماران در سی‌تی‌اسکن اسپیرال شکم و لگن با نرم‌افزار ImPACT CT Patient Dosimetry

Background: Due to the presence of radiosensitive organs in the abdominopelvic region and increasing the number of requests for CT scan examinations, concerns about increasing radiation doses in patients has been greatly elevated. Therefore, the goal of this study was to determine the absorbed dose of radiosensitive organs and the effective dose in patients underwent abdominopelvic CT scan usin...

متن کامل

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

Body CT scanning in young adults: examination indications, patient outcomes, and risk of radiation-induced cancer.

PURPOSE To quantify patient outcome and predicted cancer risk from body computed tomography (CT) in young adults and identify common indications for the imaging examination. MATERIALS AND METHODS This retrospective multicenter study was HIPAA compliant and approved by the institutional review boards of three institutions, with waiver of informed consent. The Research Patient Data Registry con...

متن کامل

Diagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey

Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2018