Clinical comparison of frequency doubling technology perimetry and Humphrey perimetry.

نویسندگان

  • R Casson
  • B James
  • A Rubinstein
  • H Ali
چکیده

AIM To determine the number of missed points on frequency doubling technology (FDT) perimetry that optimise the sensitivity and specificity of the test and to determine the topographical accuracy of the test in a clinical setting. METHODS In a prospective study, the perimetric data from 99 patients who underwent both FDT perimetry in the screening mode and Humphrey 24-2 (H24-2) were used to determine the sensitivity and specificity of the FDT perimetry compared with the full threshold H24-2 as the gold standard. RESULTS Missed points on the FDT perimetry correlated with both the mean deviation and the corrected pattern standard deviation on the Humphrey perimetry. A score assigned to abnormal points on the FDT perimetry and the Humphrey total deviation plot showed a significant correlation for both the location and the depth of the defect. In comparing the Humphrey hemifield test with the FDT perimetry results, if at least one missed point on the frequency doubling test was considered as abnormal then the overall sensitivity of the test was 78.1% and the specificity was 89.1%. CONCLUSION FDT perimetry in the screening mode performed in a clinical setting was highly specific, exhibited reasonable sensitivity, and accurately determined the location and depth of scotomas when compared with the full threshold Humphrey 24-2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of the Effects of Neutral Density Filters and Diffusing Filters on Motion Detection Perimetry, White-on-white Perimetry and Frequency Doubling Perimetry

Background: Motion detection perimetry and frequency doubling perimetry are methods that have been developed with the goal of detecting glaucomatous field defects earlier than conventional white-on-white perimetry. It is well recognized that the development of cataract and pupillary constriction can significantly influence perimetric thresholds when screening for, or following the progression o...

متن کامل

A comparison of perimetric results with the Medmont and Humphrey perimeters.

BACKGROUND The Humphrey field analyser (HFA), Humphrey-Zeiss frequency doubling perimeter, and the Medmont automated perimeter (MAP) are three commonly used automated perimeters with threshold achromatic methodologies. Visual field loss may be detected earlier with strategies that target cell lines with reduced redundancy or which suffer selective damage. METHOD To compare these three perimet...

متن کامل

Screening for glaucoma with frequency-doubling technology and Damato campimetry.

OBJECTIVE To assess frequency-doubling technology (FDT) perimetry (Humphrey Systems, San Leandro, Calif) and Damato campimetry (Precision Vision, Villa Park, Ill) for detecting glaucoma in a public glaucoma screening. METHODS A 2-day public glaucoma screening was held at 2 different institutions. Each subject underwent 2 visual field screening tests (Damato campimetry and FDT perimetry in scr...

متن کامل

EXTENDED REPORT Clinical evaluation of frequency doubling technology perimetry using the Humphrey Matrix 24-2 threshold strategy

Aims: To evaluate performance of frequency doubling technology (FDT) perimetry using the Humphrey Matrix 24-2 thresholding program in a hospital eye service (HES) glaucoma clinic. Methods: A random sample of individuals referred consecutively to the HES for suspected glaucoma were examined with 24-2 threshold FDT in addition to routine clinical tests. The discriminatory power of FDT and standar...

متن کامل

Frequency Doubling Technology vs Standard Automated Perimetry in Ocular Hypertensive Patients

BACKGROUND Frequency doubling technology (FDT) perimetry measures contrast sensitivity. The magnocellular component of ganglion cells in human retina is isolated as a whole by the FDT stimulus. The aim of this study is to investigate the role of Humphrey Matrix threshold testing in the detection of early functional retinal impairment in ocular hypertensive patients compared to standard automate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 85 3  شماره 

صفحات  -

تاریخ انتشار 2001