Randoms variance reduction in 3D PET.

نویسندگان

  • R D Badawi
  • M P Miller
  • D L Bailey
  • P K Marsden
چکیده

In positron emission tomography (PET), random coincidence events must be removed from the measured signal in order to obtain quantitatively accurate data. The most widely implemented technique for estimating the number of random coincidences on a particular line of response is the delayed coincidence channel method. Estimates obtained in this way are subject to Poisson noise, which then propagates into the final image when the estimates are subtracted from the prompt signal. However, this noise may be reduced if variance reduction techniques similar to those used in normalization of PET detectors are applied to the randoms estimates prior to use. We have investigated the effects of randoms variance reduction on noise-equivalent count (NEC) rates on a whole-body PET camera operating in 3D mode. NEC rates were calculated using a range of phantoms representative of situations that might be encountered clinically. We have also investigated the properties of three randoms variance reduction methods (based on algorithms previously used for normalization) in terms of their systematic accuracy and their variance reduction efficacy, both in phantom studies and in vivo. Those algorithms investigated that do not make assumptions about the spatial distribution of random coincidences give the best estimates of the randoms distribution. With the camera used, which has a limited axial extent (10.8 cm) and a large ring diameter (102 cm), the gains in image signal-to-noise ratio obtained with this technique ranged from approximately 5% to approximately 15%, depending on object size, activity distribution and the amount of activity in the field of view. Larger gains would be expected if this technique were to be employed on cameras of greater axial extent and smaller ring diameter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Statistical Models for Randoms - Precorrected PET

PET measurements are usually precorrected for accidental coincidence events by real-time subtraction of the delayed window coincidences. Randoms subtraction compensates in mean for accidental coincidences but destroys the Poisson statistics. We propose and analyze two new approximations to the exact log-likelihood of the precorrected measurements, one based on a \shifted Poisson" model, the oth...

متن کامل

New Statistical Models for Randoms-Precorrected PET Scans

PET measurements are usually precorrected for accidental coincidence events by real-time subtraction of the delayed window coincidences. Randoms subtraction compensates in mean for accidental coincidences but destroys the Poisson statistics. We propose and analyze two new approximations to the exact log-likelihood of the precorrected measurements, one based on a “shifted Poisson” model, the oth...

متن کامل

Statistical Tomographic Image Reconstruction Methods for Randoms-Precorrected PET Measurements

Statistical Tomographic Image Reconstruction Methods for Randoms-Precorrected PET Measurements

متن کامل

Statistical image reconstruction methods for randoms-precorrected PET scans

Positron emission tomography (PET) measurements are usually precorrected for accidental coincidence events by real-time subtraction of the delayed-window coincidences. Randoms subtraction compensates on average for accidental coincidences but destroys the Poisson statistics. We propose and analyze two new approximations to the exact log-likelihood of the precorrected measurements, one based on ...

متن کامل

A scatter-corrected list-mode reconstruction and a practical scatter/random approximation technique for dynamic PET imaging.

We describe an ordinary Poisson list-mode expectation maximization (OP-LMEM) algorithm with a sinogram-based scatter correction method based on the single scatter simulation (SSS) technique and a random correction method based on the variance-reduced delayed-coincidence technique. We also describe a practical approximate scatter and random-estimation approach for dynamic PET studies based on a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 44 4  شماره 

صفحات  -

تاریخ انتشار 1999