Improving thromboprophylaxis using atrial fibrillation diagnostic capabilities in implantable cardioverter-defibrillators: the multicentre Italian ANGELS of AF Project.
نویسندگان
چکیده
BACKGROUND Atrial fibrillation (AF) is a well-established risk factor for stroke and thromboembolism and is a frequent comorbid arrhythmia in patients with implantable cardioverter-defibrillators (ICDs). The Anticoagulation Use Evaluation and Life Threatening Events Sentinels (ANGELS) of AF project was a medical care program aimed at supporting adherence to oral anticoagulation (OAC) guidelines for thromboprophylaxis through the use of ICD AF diagnostics. METHODS AND RESULTS Fifty Italian cardiology clinics followed 3438 patients with ICDs. In a subgroup of 15 centers (the ANGELS of AF centers), cardiologists attending to follow-up visits were supplied with specific reports describing stroke risk factors and risk scores (American College of Chest Physicians and CHADS(2) [congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, and prior stroke or transient ischemic attack]), AF occurrence and duration, and current antithrombotic therapy for patients with AF, especially those with a CHADS(2) score >0 and not on OAC therapy. The remaining centers represented a control group of patients as a comparison of OAC use. In the ANGELS of AF centers, 709 (36%) patients had AF described either in their clinical history (n=426 [22%]) or as new-onset AF (n=257 [14%]). Among 683 (96%) patients with CHADS2 score >0, 209 (30.6%) were not taking an OAC. Appropriate OAC therapy was prescribed in 10% (22/209) of patients after evaluation of ANGELS of AF reports. The percentage of patients on OAC therapy, as indicated by guidelines, increased during follow-up from 46.1% at baseline, to 69.4% at the stroke risk evaluation phase, to up to 72.6% at the end of the observation period. In control centers, corresponding figures were 46.9% at baseline and 56.8% at the end of the observation period (P<0.001 versus ANGELS of AF group). CONCLUSIONS The ANGELS of AF project demonstrates the possibility to improve OAC use in accordance with available guidelines for stroke risk reduction in AF by supplying attending physicians with reports about patients risk factors and AF information from continuous ICD monitoring.
منابع مشابه
Twiddler syndrome causing an inappropriate implantable cardioverter-defibrillator shock.
Yang S, Bailleul C, Morillo CA, Carlson M, Themeles E, Kaufman ES, Hohnloser SH. Subclinical atrial fibrillation and the risk of stroke. N Engl J Med 2012;366:120–129. 14. Allison PD. Survival Analysis Using the SAS: A Practical Guide. 1st ed. Gary, NC: SAS Institute Inc., 1995. 15. Lamas G.Howmuchatrial fibrillation is too muchatrial fibrillation?N Engl JMed 2012; 366:178–180. 16. Hindricks G,...
متن کاملMaking a Splash?
ver the past decade, implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) device platforms have been expanded to include a host of new integrated device-based diagnostic capabilities.1 Parameters such as a sustained drop in intrathoracic impedance, reduced heart rate variability, high resting heart rate, decreased patient activity, prolonged periods of atrial...
متن کاملDual‐chamber implantable cardioverter–defibrillator. Is it useful in patient with permanent atrial fibrillation?
In patients with permanent atrial fibrillation (AF) and implantable cardioverter-defibrillator (ICD) implant indication, a single-chamber device is the choice because AF does not provide interesting information for the treatment. It is very unusual to find patients with permanent AF that coexist with atrial tachycardia with various degree of Atrioventricular block.
متن کاملAtrial fibrillation in patients with implantable defibrillators.
Atrial fibrillation (AF) is common in patients who have implantable defibrillators and presents some unique challenges and opportunities. AF burden can be assessed more accurately, allowing for evaluation of therapy efficacy (drugs or ablation). It remains to be shown whether home monitoring of defibrillators to detect and treat AF more quickly can reduce cardiovascular and stroke end points. O...
متن کاملAtrial Sensing and Blanking in Dual-Chamber Implantable Cardioverter-Defibrillators
Atrial Sensing and Blanking in Dual-Chamber Implantable Cardioverter-Defibrillators Accurate atrial sensing during tachycardia is essential for reliable determination of atrial rate, which is a critical component of interval-based dual-chamber supraventricular tachycardia (SVT)–VT discrimination algorithms. Thus, atrial sensing in dual-chamber implantable cardioverter-defibrillators (ICDs) must...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular quality and outcomes
دوره 5 2 شماره
صفحات -
تاریخ انتشار 2012