Automated Cryo-tomography and Single Particle Analysis with a New Type of Phase Plate
نویسندگان
چکیده
Recent years have shown an increased interest in the development and use of phase plates in cryo-EM. The oldest and the most productive type of phase plate is the carbon film Zernike phase plate [1]. It has been successfully used in cryo-tomography [2] and single particle analysis applications [3]. Despite its good performance the Zernike phase plate has a few pitfalls. One major practical hindrance is its short lifetime [4]. Typically within 10 days after being installed into the microscope its performance deteriorates to the point where it has to be exchanged. Another disadvantage of the Zernike phase plate is that it produces fringes around high-contrast features in the image, such as lipid membranes, support film edges etc [5]. Despite its shortcomings the Zernike phase plate has been the main motivation and experience generator in the last years.
منابع مشابه
Phase Contrast Cryo-Electron Tomography and Single Particle Analysis with a New Phase Plate
Biological samples are very sensitive to beam irradiation because of induced changes to their structure by the incident electron. Due to the limited allowed dose, cryo-images of frozen-hydrated biological specimens are typically noisy and low in contrast. One way to improve the imaging of such samples is by using a phase plate to increase contrast and signal-to-noise ratio. The improved contras...
متن کاملArtifact Correction for Zernike Phase-Plate Cryo-Electron Tomography
In cryo-electron microscopy (cryo-EM), vitreously frozen biological specimens can tolerate only a limited electron dose for imaging. Therefore, cryo-EM micrographs display weak contrast and a poor signal-to-noise ratio. This limits data interpretability and prevents efficient application of cryo-EM to a wider range of biological problems. Continued efforts have been invested in imaging methods ...
متن کاملPhase Contrast Subtomogram Averaging at Sub-nm Resolution
Phase contrast imaging is a powerful technique that can increase the signal to noise ratio and contrast of the phase objects in their native and frozen hydrated state. The improved contrast is as a result of the phase shift between the unscattered and the scattered electron beams. The so called Volta phase plate (VPP) is a newly developed thin film phase plate which has advantages compared to t...
متن کاملHigh Throughput Fabrication Process of a Zernike Phase Plate
In transmission electron microscopy (TEM) for biological and polymer samples, it is difficult to image with high contrast, since they are mostly composed of light elements and have similar density. One solution to enhance the contrast is utilization of phase contrast microscopy, which is realized in optical microscopy. Accordingly, many types of phase plates for electron microscopy have been pr...
متن کاملAdvances in phase plate cryo-EM imaging of DNA and nucleosomes
Contrast in electron cryo-microscopy (cryo-EM) is limited by the weak phase and radiation sensitive nature of biologic samples embedded in vitrified ice. We have recently shown that a new contrast enhancement technique utilizing the Volta phase plate can be combined with single particle analysis to determine the structure of a small chromatin complex, the nucleosome core particle, at near-atomi...
متن کامل