The reliability of knee joint position testing using electrogoniometry
نویسندگان
چکیده
BACKGROUND The current investigation examined the inter- and intra-tester reliability of knee joint angle measurements using a flexible Penny and Giles Biometric electrogoniometer. The clinical utility of electrogoniometry was also addressed. METHODS The first study examined the inter- and intra-tester reliability of measurements of knee joint angles in supine, sitting and standing in 35 healthy adults. The second study evaluated inter-tester and intra-tester reliability of knee joint angle measurements in standing and after walking 10 metres in 20 healthy adults, using an enhanced measurement protocol with a more detailed electrogoniometer attachment procedure. Both inter-tester reliability studies involved two testers. RESULTS In the first study, inter-tester reliability (ICC[2,10]) ranged from 0.58-0.71 in supine, 0.68-0.79 in sitting and 0.57-0.80 in standing. The standard error of measurement between testers was less than 3.55 degrees and the limits of agreement ranged from -12.51 degrees to 12.21 degrees . Reliability coefficients for intra-tester reliability (ICC[3,10]) ranged from 0.75-0.76 in supine, 0.86-0.87 in sitting and 0.87-0.88 in standing. The standard error of measurement for repeated measures by the same tester was less than 1.7 degrees and the limits of agreement ranged from -8.13 degrees to 7.90 degrees . The second study showed that using a more detailed electrogoniometer attachment protocol reduced the error of measurement between testers to 0.5 degrees . CONCLUSION Using a standardised protocol, reliable measures of knee joint angles can be gained in standing, supine and sitting by using a flexible goniometer.
منابع مشابه
The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) in Persian Speaking Patients with Knee Osteoarthritis
Background: Osteoarthritis of the knee is the most common chronic joint disease that involves middle aged and elderly persons. There are different clinical instruments to quantify the health status of patients with knee osteoarthritis and one example is the WOMAC score that has been translated and adapted into different languages. The purpose of this study was cultural adaptation, validation ...
متن کاملMovement of the knee in osteoarthritis. The use of electrogoniometry to assess function.
We used electrogoniometers to measure the range of movement (ROM) of the knee during various activities, comparing 50 patients with osteoarthritis of the knee (OA) with 20 healthy age- and sex-matched subjects. The minimum and maximum joint angles and the ranges of excursion of the patient and control groups were tested for significant differences, using an unrelated Student's t-test with poole...
متن کاملThe Acute Effect of Static Stretching of Quadriceps, Hamstrings and Gastrocnemius Muscles on Knee Joint Position Sense in Football Players
Purpose: Everything that impairs joint proprioception system can harm joints. It has been stated that stretching exercises can change properties of the proprioceptive receptors and as a result changes the sensibility of the joints proprioception. Due to fact that static stretching has greater use between athletes, it is necessary to give useful information about the safety of these stretch...
متن کاملInvestigating Knee Joint Position Sense in a Male Soccer Player After Anterior Cruciate Ligament Reconstruction
Background: Anterior Cruciate Ligament) ACL (injury is the most prevalent knee ligament injury during exercise, with a frequency of 36.9 per 100000 individuals. The one characteristic of this injury is proprioception dysfunction. The current study investigated the knee proprioception in soccer players after ACL reconstruction. Methods: The study participants consisted of 20 elite male soccer p...
متن کاملPsychometric properties of measurement tools for quantifying knee joint position and movement: a systematic review.
This systematic review critically evaluates literature on the reliability and validity of measurement tools for quantifying knee joint angles and knee movement. A search was conducted of seven medical databases and one biomedical engineering database, yielding 43 articles that reported reliability or validity. Tools for quantifying knee joint angles included standard handheld goniometers, fluid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMC Musculoskeletal Disorders
دوره 9 شماره
صفحات -
تاریخ انتشار 2008